EN
21
1. The fireplace must be permanently bolted to
the floor of the Mobile Home using
the floor screws
provided.
2. The fireplace must have a permanent outside air source
for combustion.
3. The fireplace must be electrically grounded to the steel
chassis of the Mobile Home.
4. A listed double-wall connector chimney system, roof
thimble, spark arrestor and roof flashing kit suitable for
use in Mobile Homes must be used.
5. The chimney shall be attached directly to the room
heater and shall extend at least 3 ft. (914mm) above
the part of the roof through which it passes. The top of
the chimney should project at least 2ft. (610mm) above
the highest elevation of any part of the Mobile Home
within 10 ft. (3048mm) of the chimney.
6. The chimney system shall comply with Local
Requirements.
7. Any openings in a chimney guard where required must
not permit the entrance of 3/4" (19mm) diameter rod.
8. CAUTION: THE STRUCTURAL INTEGRITY OF THE MOBILE
HOME ROOF, FLOOR, WALLS AND CEILING MUST BE
MAINTAINED.
9. Check any other local building code as other local codes
may apply.
10. WARNING: DO NOT INSTALL IN A SLEEPING ROOM OF A
MOBILE HOME.
11. Use silicone to create an effective vapour barrier at
the location where the chimney or other component
penetrates to the exterior of the structure.
CAUTION:
At no time use unlabelled parts, or
substitute parts made for another chimney system.
Install as per chimney manufacturer's installation
instructions.
WARNING:
Operate only with door fully
closed - open feed door to feed fire only.
1. Identify the position of the outside air damper by the
orientation of the metal handle that rests outside the
galvanized pipe. The metal handle and the damper
disc are in line with each other. This means that if the
metal handle is in a horizontal position, the damper is
flat and fully open.
Permanent Outside
Air Inlet
In addition to standard installation instructions the
following requirements are mandatory for installation
in a mobile home.
installation
Содержание Contura Ri50
Страница 29: ...EN 29 3 4 x 8 Nut M5 Tool 8 mm or 5 16 wrench x 8 M5 x 12 Allen screw 3mm or 3 32 installation ...
Страница 30: ...EN 30 5 6 8 mm wrench or use crescent wrench installation ...
Страница 40: ...1 2 3 4 EN 40 Installing the firebox cladding installation ...
Страница 41: ...7 5 6 8 EN 41 installation ...
Страница 42: ...11 9 10 EN 42 installation ...
Страница 50: ...EN 50 maintenance ...
Страница 51: ...EN 51 Replace front glass First 2 1 Remove side glass maintenance ...
Страница 52: ...EN 52 maintenance ...
Страница 53: ...EN 53 Replace gasket door First 3 1 2 Remove side glass Remove front glass maintenance ...
Страница 54: ...EN 54 maintenance ...
Страница 55: ...EN 55 maintenance ...
Страница 56: ...EN 56 maintenance ...
Страница 57: ...EN 57 PRESS PRESS maintenance ...
Страница 58: ...EN 58 maintenance ...
Страница 59: ...EN 59 Remove gasket back 4 maintenance ...
Страница 60: ...EN 60 maintenance ...
Страница 61: ...EN 61 Remove door 5 maintenance ...
Страница 62: ...EN 62 maintenance ...
Страница 63: ...EN 63 maintenance ...
Страница 64: ...EN 64 Replace Guillotine mechanism First 6 1 4 5 Remove side glass Remove gasket back Remove door maintenance ...
Страница 65: ...EN 65 maintenance ...
Страница 66: ...EN 66 maintenance ...
Страница 67: ...391697 Assembled Door Spare part number EN 67 Replacement parts parts list ...
Страница 68: ...EN 68 Replacement parts Left or Right parts list ...
Страница 73: ...EN 73 30 30 298670 Air flow panel 31 398929 Radiation Shield Back 34 603144 Wire Door Opening 31 34 parts list ...
Страница 77: ...NOTES ...
Страница 79: ......
Страница 80: ...NOTES ...
Страница 81: ...EN 81 notes ...
Страница 82: ...EN 82 notes ...
Страница 83: ......