Start with a solid-pak listed factory built chimney section at least
12" (304 mm) long, with insulation of 1" (25.4 mm) or more, and
an inside diameter of 8" (2 inches [51 mm] larger than the 6"
[152.4 mm] chimney connector). Use this as a pass-through for
a minimum 24-gage single wall steel chimney connector. Keep
solid-pak section concentric with and spaced 1" (25.4 mm) off the
chimney connector by way of sheet metal support plates at both
ends of chimney section. Cover opening with and support chimney
section on both sides with 24 gage minimum sheet metal supports.
See that the supports are fastened securely to wall surfaces on all
sides. Make sure fasteners are used to secure chimney flue liner.
Starting with a minimum 24 gage (.024" [.61 mm]) 6" (152.4 mm)
metal chimney connector, and a minimum 24 gage ventilated
wall thimble which has two air channels of 1" (25.4 mm) each,
construct a wall pass-through. There shall be a minimum 6"
(152.4) mm separation area containing fiberglass insulation,
from the outer surface of the wall thimble to wall combustibles.
Support the wall thimble, and cover its opening with a 24-gage
minimum sheet metal support. Maintain the 6" (152.4 mm) space.
There should also be a support sized to fit and hold the metal
chimney connector. See that the supports are fastened securely to
wall surfaces on all sides. Make sure fasteners used to secure the
metal chimney connector do not penetrate chimney flue liner.
Method C:
6" (152.4 mm) Clearance to Combustible Wall Member:
Method D:
2" (50.8 mm) Clearance to Combustible Wall Member:
Minimum chimney clearance
to sheet steel supports and combustibles 2" (51 mm)
Chimney connector
Chimney
connector
Chimney length
Chimney section
Minimum clearance 2" (51 mm)
1" (25,4 mm) air space to chimney length
Masonry chimney
Chimney F
lue
Sheet steel supports
Sheet steel supports
Air space
2"(51 mm)
Minimum chimney clearance to brick
and combustibles 2" (51 mm)
Minimum 6" (152 mm)
of glass fibre insulation
Two air channels each 1" (25 mm)
Two ventilated air channels
each 1" (25 mm)
Constructed of sheet steel
Chimney connector
Masonry chimney
Ch
imn
ey Flu
e
Sheet steel supports
EN
18
installation
Содержание Contura Ri50
Страница 29: ...EN 29 3 4 x 8 Nut M5 Tool 8 mm or 5 16 wrench x 8 M5 x 12 Allen screw 3mm or 3 32 installation ...
Страница 30: ...EN 30 5 6 8 mm wrench or use crescent wrench installation ...
Страница 40: ...1 2 3 4 EN 40 Installing the firebox cladding installation ...
Страница 41: ...7 5 6 8 EN 41 installation ...
Страница 42: ...11 9 10 EN 42 installation ...
Страница 50: ...EN 50 maintenance ...
Страница 51: ...EN 51 Replace front glass First 2 1 Remove side glass maintenance ...
Страница 52: ...EN 52 maintenance ...
Страница 53: ...EN 53 Replace gasket door First 3 1 2 Remove side glass Remove front glass maintenance ...
Страница 54: ...EN 54 maintenance ...
Страница 55: ...EN 55 maintenance ...
Страница 56: ...EN 56 maintenance ...
Страница 57: ...EN 57 PRESS PRESS maintenance ...
Страница 58: ...EN 58 maintenance ...
Страница 59: ...EN 59 Remove gasket back 4 maintenance ...
Страница 60: ...EN 60 maintenance ...
Страница 61: ...EN 61 Remove door 5 maintenance ...
Страница 62: ...EN 62 maintenance ...
Страница 63: ...EN 63 maintenance ...
Страница 64: ...EN 64 Replace Guillotine mechanism First 6 1 4 5 Remove side glass Remove gasket back Remove door maintenance ...
Страница 65: ...EN 65 maintenance ...
Страница 66: ...EN 66 maintenance ...
Страница 67: ...391697 Assembled Door Spare part number EN 67 Replacement parts parts list ...
Страница 68: ...EN 68 Replacement parts Left or Right parts list ...
Страница 73: ...EN 73 30 30 298670 Air flow panel 31 398929 Radiation Shield Back 34 603144 Wire Door Opening 31 34 parts list ...
Страница 77: ...NOTES ...
Страница 79: ......
Страница 80: ...NOTES ...
Страница 81: ...EN 81 notes ...
Страница 82: ...EN 82 notes ...
Страница 83: ......