City Series ACV60E
|
31
installation
Framing Dimensions
NOTE: Framing may be constructed of combustible material (I.e. 2 x 4) and does not require steel studs.
Framing
Dimensions
Description
ACV60E
A
Framing Height
1137 mm
B*
Framing Width
1668 mm
C*
Framing Depth
516 mm
D
Minimum Height to Combustibles
2038 mm
E
Corner Wall Depth
1866 mm
F
Corner Facing Wall Depth
2638 mm
G
Vent Centerline Height
1478 mm
I
Gas Connection Opening Height
See gas connection location in this manual
J
Gas Connection Height
See gas connection location in this manual
K
Gas Connection Inset-Centre Opening
See gas connection location in this manual
L
Gas Connection Opening Width
See gas connection location in this manual
** See manual for alternate Gas/ Electrical connection options
Note: A combined minimum of
1168 square cm of open area
is required for the convection
air outlet to cool the enclosure.
Ensure clearances for convec-
tion air outlets are met.
See clearances in this manual
for different ways to achieve
this.
Note: This appliance must be
installed on a solid surface
such as a plywood floor
which must be the full width
and depth of the appliance.
The lift handles add approximately 102mm to the width of the appliance. If the appliance will be lifted off the ground and slid into the framed opening, we sug-
gest changing the framing width from 1168mm to 1770mm to allow the appliance to slide into position with the handles on, or creating a platform in front of
the framed opening where the lift handles can be removed prior to installation. If the framing is raised off the ground you can install it after the appliance is in
place with handles removed to maintain the framing width of 1668mm. Ensure that the wood base for the appliance is strong enough to support its shipping
weight of 210kg.
|
City Series CV60E
installation
Framing Dimensions CV60E
NOTE:
Framing may be constructed of combustible material (ie. 2 x 4)and does not require steel studs.
Framing
Dimensions
Description
CV60E
A
Framing Height
44 3/4" (1137mm)
B
Framing Width
65 11/16" (1668mm)
C
Framing Depth
20-5/16" (516mm)
D
Minimum Height to Combustibles
81 1/4"(2038mm)
E
Corner Wall Depth
73 7/16” (1866mm)
F
Corner Facing Wall Width
103 7/8" (2638mm)
G
Vent Centerline Height
58 3/16" (1478mm)
I
Gas Connection Opening Height
See gas connection location in this manual
See gas connection location in this manual
See gas connection location in this manual
See gas connection location in this manual
J
Gas Connection Height
K
Gas Connection Inset-Centre Opening
L
Gas Connection Opening Width
Note: A combined minimum
of 180 square inches of open
area is required for the con-
vection air outlet to cool the
enclosure. Ensure clearances
for Convection Air Outlets
are met.
See clearances CV60E in this
manual as there are different
methods as to how this can
be achieved.
Note: This appliance must be
installed on a solid surface
such as a plywood floor
which must be the full width
and depth of the appliance.
With the lift handles adding approximately 4 inches to the overall width of the appliance,In cases where the appliance would need to
be raised off the ground
in order to slide it into the framed opening, it is suggested that either the framing width change 65 11/16 to 69 11/16 “ so appliance could be easily slid into
position with the handles remaining on the appliance, or alternatively create a platform in front of the framed opening where the lift handles could be removed
prior to sliding the appliance into its final position. Alternatively, If raised off the ground, the framing could be installed afterwards once appliance has been
put into place and handles removed in order to keep framing width at 65 11/16”.. Ensure that the wood base that the appliance will sit on is strong enough
to support the full weight of this appliance. The overall weight of this appliance is 480 pounds (shipping weight).
*
*
* T
he framing depth/width does not take into account plasterboard/wood or similar materials against the back /side wall.
The framing depth will need to change based on the thickness of the material.
Example: B - 65 11/16" framing width +13 mm plasterboard per side = 66 11/16")
Example: C - 20 5/16" framing depth +13 mm plasterboard = 20 13/16")