CI2600/HI400 | wood insert
|
37
maintenance
CAST BYPASS TOP PLATE REMOVAL /
INSTALLATION
1.
Allow the stove to burn out and cool down, until cool to touch.
2.
Open stove door to access secondary air tube.
3.
Remove secondary air tube–(see previous page).
4.
Remove 2 bolts in locations shown and remove stainless steel front lip.
retainer.
5.
8 bolts secure the cast bypass top plate to the roof of the stove.
Before removing the bolts securing the cast bypass - support the cast up
with 2 X 12-1/4" 2 x 4 's. The cast bypass opening weighs 30lbs -
DO
NOT REMOVE
the bolts on the cast bypass prior to supporting the weight
to avoid damage and injury.
6
. Remove the cast bypass opening top plate and replace.
7
. Reverse steps to reinstall.
Stainless front lip retainer
View of inside top of stove
View of inside top of stove
Cast bypass opening