Regal Smartvalve 7001 Скачать руководство пользователя страница 2

CHLORINATORS INCORPORATED  

ONE (1) YEAR LIMITED WARRANTY

 

 

Chlorinators Incorporated (hereinafter called “C.I.”) sets forth 
the follow ing warranties with respect to its REGAL Series 
7000 SMARTVALVE™. This war ranty does not apply to the            
purchase of spare parts or other services performed by C.I. or 
its authorized dealers. This represents the entire agreement 
between C.I. and Buyer (also referred to as “end-user”) and 
shall apply unless modified in writing and signed by a                                   
C.I. Officer, and this warranty and its intended terms shall 
supersede any prior negotiations, correspondence, understand ings, 
or agreements, written or oral. The Buyer agrees to and 
accepts all terms of this warranty by its contracting for or 
acceptance of C.I.’s prod ucts, and forms or other documents or 
statements issued by Buyer or any other person shall not modify 
or otherwise affect any of the following terms. Buyer should be 
aware that reseller must rely entirely upon Chlo 

rinators 

Incorporated’s warranties, or assume their own responsibility.  
 

The following states C.I.’s entire warranty and 
represents Buyer’s exclu 

sive remedy with 

respect to its product. Such warranties are 
expressly given in lieu of any other warranty, 
expressed or implied, including but not limited 
to those of merchantability and fitness for                       
a particular purpose. This expressed warranty   
or any other warranty implied by law shall               
not cover defects due to accident, improper use, 
or non-compliance with C.I.’s operating and 
main 

tenance, assembly, installation manual 

and instructions.

 

 
Recommendations and advice as to specifications, capabilities, 
design, in 

stallation, engineering, application, and use of                       

products are provided as an accommodation and are intended 
only as suggestions. C.I. assumes no lia 

bility for such                               

recommendations and advice and they are not to be con strued 
as constituting any warranty, expressed or implied.

 

 
 

 TERMS OF WARRANTY 

 
C.I. warrants its REGAL Series 7000 SMARTVALVE™ for   
a period of one (1) year from date of shipment from C.I. Date 
of shipment from the factory shall be determined solely on             
the basis of the serial code affixed to the SMARTVALVE’s 
enclosure. The serial number contains a date code. All serial 
numbers are also registered by Chlorinators Incorporated as to 
date of shipment, model number, accessories, options, and 
billing name. If the serial number is missing, defaced, changed, 
or in any way ren dered un readable, Chlorinators Incorporated 
shall, at its option, have the right to declare the warranty void. 
If the serial number does not match the regis 

tered model               

number as to, but not limited to, such items as accessories or 
options, the same shall apply. 
 
The warranty shall apply against material defects in                                 
components and work 

manship occurring in the course of           

manufacture. Buyer’s sole remedy for breach of said warranty 
shall be, at C.I.’s option, either repair or replace ment of any 
unit which is received by C.I. at its plant in Stuart, Florida 
(shipping charges prepaid by buyer), within the time period set 
forth above and which is found by C.I. to be defective by                     
reason of manufacture. 

 

 

 

Not withstanding the foregoing, C.I. shall not 
be liable to Buyer for damages, including           
personal injury or death to any person or             
persons, or claims of any kind by a third party 
or property damage or loss of business or             
profits. In no event shall C.I. be liable to Buyer 
for consequential or accidental damages of 
any kind, even if C.I. was aware of the           
possibility of such damages. There are no 
remedies except those set forth. Further, that 
there are no other authorized warranty repair 
facilities other than those at the Chlorinators 
Incorporated factory in Stuart, Florida.

 

 

 EXCLUSIONS

 

 

The following are considered external environmental factors beyond 
the control of C.I., and which may cause damage and/or need for                     
service which will be specifically excluded from this warranty (i.e., not 
a material defect in components and workmanship occurring in the 
course of manufacture). 

 
1. Damage by extraneous causes such as fire, water, lightning,                 

chemical or galvanic attack, etc. 

 
2. Damage to the circuit boards or internal components incurred by 

drilling the enclosure for field wiring. 

  
3. Damage due to the connection of power lines to low voltage signal       

terminals. 

 
4. Physical damage due to force, dropping, misuse or other abuse. 

 
5. Use other than that as described in this Instruction Manual                 

(misapplication). 

  
6. Repair by someone other than Chlorinators Incorporated. 

 
7. Improperly installed. 

 
8. This warranty 

DOES NOT

 cover wear items subject to periodic 

replacement such as sensors, generating cells, fuses, batteries,                   
o-rings, gaskets, seals, packing, etc.  

 
The exclusions listed above are provided for purposes of clarification,   
and are not intended to, in any way, limit or eliminate other possible     
exclu sions.

 

  

 

 NO OTHER WARRANTIES

 

 

Unless otherwise explicitly agreed in writing, and signed by a C.I.                   
officer, it is understood that this is the only written warranty given by 
C.I. for the systems and components stated. 

 

 

The dealers or representatives of C.I. may not 
make verbal representations that add, modify 
or change the written warranties contained 
herein or change the extent and nature of C.I.’s 
liability. In no event shall C.I. be liable for direct, 
consequential, special, incidental or punitive 
damages of any kind with respect to the product, 
including but not limited to those which may 
allegedly arise out of breach of warran 

ty, 

breach of contract, negligence, strict liability, 
or any other law, gov ernmental regulation, or 
court decision, except as provided herein.

2

Содержание Smartvalve 7001

Страница 1: ...nt is suitable for use only with the gases specified DO NOT USE THIS EQUIPMENT WITH OTHER GASES Such use can result in failures having hazardous consequences 2 This equipment is designed FOR VACUUM SE...

Страница 2: ...against material defects in components and workmanship occurring in the course of manufacture Buyer s sole remedy for breach of said warranty shall be at C I s option either repair or replacement of...

Страница 3: ...ct to open or close the valve 8 Do not reuse lead gaskets They may not seal properly thereby permitting the release of gas 9 Use only lead gaskets Other types may contract with temperature variations...

Страница 4: ...ing the Analog Output C Setting the Mechanical Zero 8 0 MAINTENANCE 9 0 SPECIFICATIONS A To Enter the Configuration Mode B Configuration Parameters C To Exit the Configuration Mode 5 0 CONFIGURATION M...

Страница 5: ...ly Circuit Board Part No 7071 Drawing No 7 Use of External Surge Suppressors Consult manufacturer of surge suppressor for installation and wiring specifics Drawing No 8 Control Valve Assembly for 10 t...

Страница 6: ...the middle third of the system s capacity maximum feed rate 2 The water flow meter and transmitter must be sized or scaled so the maximum water flow coincides with the maximum feed rate capacity of t...

Страница 7: ...ting to the vacuum fitting on the ejector assembly 5 Finally connect a length of tubing from the bottom connection of the pressure relief valve routing it outside with the end facing down and protecte...

Страница 8: ...isplay screen reads ENT ENG PW 0 Enter Engineering Password 2 Press the NEXT keypad button three times until the factory default password 0 0 0 0 appears Then press ENT enter to accept 3 The TOP LINE...

Страница 9: ...eatedly until the preferred FIRST digit is displayed Then press NEXT to accept the new value b The number 0 will appear as the second digit Once again use UP or DOWN to scroll to the preferred number...

Страница 10: ...red and designate what condition the alarm represents The selections are OFF LOW or HIGH If the SET POINT MODE setting is left in the factory default OFF position no additional parameters will be made...

Страница 11: ...ading of 0 45 V NOTE A voltage reading from 0 41 to 0 49 is acceptable IMPORTANT If for some reason the voltage reading falls outside of the acceptable range contact Chlorinators Incorporated for assi...

Страница 12: ...t the feed rate simply turn the thumbwheel while using the remote meter ball float as a guide 4 Fully Manual If it is necessary to temporarily bypass the SMARTVALVE entirely use the remote meter rate...

Страница 13: ...t Press ESC a second time and SAVE CHANGES to return to the main operating screen C SETTING MECHANICAL ZERO See Drawing No 8 for Model 7001 or No 9 for Model 7006 The mechanical zero valve plug positi...

Страница 14: ...AM 16 Bit Display 20 character 2 line Backlit LCD Relays Three 3 each 10A 250 VAC Environmental Limits 32 to 120 F 0 to 50 C Calibration Accuracy 0 25 from zero Speed of Response Variable and field se...

Страница 15: ...Union Typ BY OTHERS Gauge for Supply Pressure Ps BY OTHERS Gauge for Back Pressure Pb BY OTHERS REGAL Model CRA 5000 Residual Analyzer REGAL VAC 1000 Vacuum Monitor Static Mixer BY OTHERS Residual Sa...

Страница 16: ...Ball Valve 1 PVC Ball Valve 3 PVC Ball Valve Chemical Solution Injection Point Water Flow Meter 4 20 mA Analog Flow Input Signal 4 20 Milliamp Analog Output Signal 1 For Automatic Operation open ball...

Страница 17: ...valve tool supplied with your REGAL chlorinator system into the slot and tilt the screwdriver in the direction of the terminal number This will open the clamp and allow the wire to be inserted Remove...

Страница 18: ...RIGHT SIDE JUNCTION BOX 1 L See Note 1 2 N See Note 1 3 Ground See Note 1 4 N O Relay K1 5 Com Relay K1 6 N C Relay K1 7 N O Relay K2 8 Com Relay K2 9 N C Relay K2 10 N O Relay K3 11 Com Relay K3 NOT...

Страница 19: ...19 DRAWING NO 5 DISPLAY CIRCUIT BOARD Part Number 7070 NOTE All wiring connections to this circuit board are made at the factory prior to shipment See Drawing No 4 for Field Wiring...

Страница 20: ...20 DRAWING NO 6 POWER RELAY CIRCUIT BOARD Part Number 7071 NOTE All wiring connections to this circuit board are made at the factory prior to shipment See Drawing No 4 for Field Wiring...

Страница 21: ...h Grounding Rod External Surge Protection Device Typ BY OTHERS IMPORTANT Consult the manufacturer of the transient voltage surge suppression device for proper wiring of inputs and outputs Analog and d...

Страница 22: ...7121 1 Potentiometer 7124 3 S 405 0 Ring 7127 1 S 414 0 Ring 7128 2 Seal 7129 1 Seal 7131 4 Screw 10 24 X 2 1 2 7132 1 Screw 10 24 X 1 2 7133 4 Screw 10 32 X 1 with O Ring 7135 5 10 Lock Washer 7136...

Страница 23: ...r 7121 1 Potentiometer 7122 1 Guide Retainer 7124 1 S 405 O Ring 7125 1 S 415 O Ring 7126 1 S 407 O Ring 7127 1 S 414 O Ring 7128 1 Seal 7129 1 Seal 7130 1 Seal 7131 4 Screw 10 24 X 2 1 2 7132 1 Screw...

Страница 24: ...24 DRAWING NO 10 ENGINEERING DATA SHEET Series 7000 SMARTVALVE Dimensions DIMENSIONS INCHES mm 7500 REMOTE METER PANEL SMARTVALVE...

Страница 25: ...e Valve Plug O Ring 11 S 406 2 Meter Tube Plug O Ring 12 Z 815 4 Screw 1 4 20 x 1 Long 13 ZZ 278 1 Plug 1 2 NPT 14 See Chart 2 Tube Fitting Elbow Not Shown NOTE If system is using 1000 PPD or 2000 PPD...

Страница 26: ...Metering Tube Float Assembly 1000 PPD 20 Kg Hr 2000 PPD 40 Kg Hr Flow Meter Inlet Block Back Panel Mounting Screws For RV 810 RV 814 Base Plate for RV 814 Rate Valve Seat Plug with 2 S 803 Seals NOTES...

Страница 27: ...pad 1 At dosage settings greater than 100 proportionality is lost at some water flow rate less than the designed maximum rate If the dosage setting is increased to 200 for example proportional control...

Страница 28: ...2019 Chlorinators Incorporated Printed in U S A Pub No 0919 3 1044 SE Dixie Cutoff Road Stuart Florida 34994 USA Phone 772 288 4854 Fax 772 287 3238 www regalchlorinators com Email regal regalchlorin...

Отзывы: