6
UP 0, UP 1, UP 2, UP 2.4, UP 2.5
• Electric actuators and their accessories must be stored in dry, well ventilated covered spaces, protected
against impurities, dust, soil humidity (by placement to racks, or on palettes), chemicals and foreign
interventions
• There shall be no corrosive gases present in the storage areas.
The of
UP X.X
are delivered in solid packages guaranteeing resistance in accordance with EN/IEC 60 654.
Package is a box. Products in boxes is possible to load on the pallets (pallet is returnable). On the outer side of
the package is stated:
•
manufacturer label,
•
name and type of product,
•
number of pieces,
•
other data – notices and stickers.
The forwarder is obliged to secure packed products, loaded on transportation means, against self-motion;
if open transportation means are used, to secure their protection against atmospheric precipitations and
splashing water. Displacement and securing of products in transportation means must provide their stable
position, exclude the possibility of their inter-collision and their collision with the vehicle walls.
Transportation can be executed by heatless and non hermetic spaces of transportation vehicles with influences
within the range:
- temperature: -25
°
C up to +70
°
C (a strange version –50 ° C up to +45 ° C)
- humidity: 5 up to 100 %, with max. water content 0,029 kg/kg of dry air
- barometric pressure 86 up to 108 kPa
After receiving EA check whether during transport or storage the actuator was not damaged.
Compare also whether the parameters on their nameplates are in accordance with accompanying
documentation or the Contract. If any discrepancy or fault occur inform immediately your supplier.
If the actuators and accessories are not immediately installed, they have to be stored in dry, well-
ventilated sheltered rooms, protected against dirt, dust, soil humidity (with placing onto shelves or onto pallets),
chemical impacts and encroachment, at ambient temperature from -10°C up to +50 °C and relative humidity
max. 80 %, in special version at temperature –50°C do +40°C.
•
It is forbidden to store EA outside or in areas not prevented against direct impact of climate.
•
Strains of the surface finishing should be promptly removed if any – it can prevent the product against
corrosion damages.
•
While storing more than one year it is necessary to check lubrication filling before the actuator is put into
operation.
•
The EA installed but not operated are to be protected the same way as when storing (e.g. with a wrapping).
•
After it is mounted onto a valve in free and wet areas or in areas where temperature is changing it is
necessary to connect the space heater – to prevent the actuator against corrosion resulted from water
condensed in the control part.
•
Remove odd conservation grease as late as before putting into operation.
1.8 Assessment of the product and packaging and removal of contamination
The product and its package are made of recycling materials. Do not throw the single parts of the package
and of the product after their life but sort them according to instructions in corresponding executives or
regulations of environment protection, and allow their recycling.
The product and its packing are not a source of any environment pollution or contamination and do not
contain any dangerous waste.
Содержание UP 0
Страница 10: ...8 UP 0 UP 1 UP 2 UP 2 4 UP 2 5 5 9 Fig 1a Fig 1b ...
Страница 11: ...UP 0 UP 1 UP 2 UP 2 4 UP 2 5 9 Fig 1c UP 2 5 with controller ...
Страница 42: ...40 UP 0 UP 1 UP 2 UP 2 4 UP 2 5 7 Enclosures 7 1 Wiring diagrams UP 1 UP 2 UP 2 4 UP 2 5 ...
Страница 43: ...UP 0 UP 1 UP 2 UP 2 4 UP 2 5 41 ...
Страница 44: ...42 UP 0 UP 1 UP 2 UP 2 4 UP 2 5 Wiring diagrams UP 0 ...
Страница 47: ...UP 0 UP 1 UP 2 UP 2 4 UP 2 5 45 7 4 Dimensional drawings Electric part turn actuators Unimact UP 0 UP 1 UP 2 ...
Страница 48: ...46 UP 0 UP 1 UP 2 UP 2 4 UP 2 5 Electric part turn actuators Unimact UP 0 UP 1 UP version stand and lever ...
Страница 49: ...UP 0 UP 1 UP 2 UP 2 4 UP 2 5 47 Electric part turn actuators Unimact UP 1 UP 2 version with local control ...
Страница 51: ...UP 0 UP 1 UP 2 UP 2 4 UP 2 5 49 Electric part turn actuators Unimact UP 2 4 UP 2 5 ...
Страница 52: ...50 UP 0 UP 1 UP 2 UP 2 4 UP 2 5 Electric part turn actuators Unimact UP 2 4 UP 2 5 version stand and lever ...
Страница 53: ...UP 0 UP 1 UP 2 UP 2 4 UP 2 5 51 Electric part turn actuators Unimact UP 2 4 UP 2 5 version with local control ...