![Regada SP 0 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/regada/sp-0/sp-0_installation-service-and-maintenance-instructions_1433055007.webp)
SP 0, SPR 0
5
(In accordance with IEC 60 364-3:1993)
the EA
SP and SPR
have to resist external effects and operate reliably:
In the conditions of the following types of environment:
•
warm mild to very hot dry with temperature in range -25
°
C to +55
°
C ....................................
AA 7*
in industrial environment:
at temperatures stated above
•
with relative humidity 10 to 100
%
, including the condensation of up to 0,029 kg water content per
1 kg of dry air at 27
°
C, with temperatures from -25
°
C up to +55
°
C .........................................
AB 7*
•
with height above sea level 2 000 m, with barometric pressure range 86 to 108 kPa..............
AC 1*
•
with spraying or jet water from all directions–(protection enclosure IP x4)...............................
AD 4*
•
with shallow dive – (product in protection IP x 7)....................................................................
AD 7*
•
with medium level of dust content – with possibility of effects of flame-proof, non-conducting and
explosion-proof dust, medium cover of dust; dust fall more than 35 but at most 350 mg/sq m. or
350 to 1000 mg/sq m per day (protection enclosure IP5x, or IP 6x| .................................................
.....................................................................................................................................
AE 5*, AE6*
•
with atmospheric occurrence of corrosive and pollution media (with high degree of atmosphere
corrosive aggressiveness); important presence of corrosive pollution.....................................
AF 2*
•
with permanent exposure of big amount of corroding or contaminated chemicals and salt fog in
execution for sea environment, for sewage water disposal plant and some chemical.......................
...............................................................................................................................................
AF 4*
•
with a possibility of influences of mechanical stress:
•
medium sinusoid vibrations with frequency in range 10 up to 150 Hz, with shift amplitude of 0,15
mm for f
<
fp and acceleration amplitude 19,6 m/s2 for f
>
fp; (transition frequency fp is from 57
up to 62 Hz) ................................................................................................
AH 2*
•
medium impacts, shocks and vibrations .........................................................................
AG 2*
•
with serious danger of plants and moulds growing ............................................................
AK 2*
•
with serious danger of animals occurrence (insects, birds, small animals) ...................
AL 2*
•
with detrimental influence of radiation:
•
of stray current with intensity of magnetic field (direct and alternating of power supply frequency)
to 400 A.m
-1
......................................................................................................
AM 2*
•
of sun radiation with intensity
>
500 a
≤
700 W/m
2
...........................................................
AN 2*
•
with effects of medium seismic activity with acceleration
>
300 Gal
≤
600 Gal ...............
AP 3*
•
with indirect danger of storm activity ...................................................................................
AQ 2*
•
with fast moving of air and strong winds .................................................................
AR 3* , AS 3*
•
with persons frequent touching earth potential (persons often touch conductive parts or they stand
on the conductive basement) ............................................................................
BC 3*
* Marking in accordance with IEC 60 364-3:1993
1.6.3 Power
s
upply and duty cycle
Power supply:
electric motor ................................................................
230/220 V AC
±10%, or
24 V AC/DC
±10%
control...........................................................................
230/220 V AC
±10%, or
24 V AC/DC
±10%
transmitter .................................................................................................................see chapter 1.8
Power supply frequency
.................................................................................... 50 Hz or 60 Hz ± 2%
Note
:
At frequency of 60 Hz operating time is reduced by 1.2 times.
Duty
cycle (according to EN (IEC) 60034-1.8):
EA SP
are designed for
remote control:
•
short-time operation
S2-10 min
•
intermitted operation
S4-25%, 6 up to 90 cycles per hour
EA SPR
are designed for
automatic regulation:
•
intermitted operation
S4-25%, 90 up to 1200 cycles per hour.
Note: EA SP is possible connect with external regulator and use it as regulated EA and for this EA stand
duty cycle and power parameters like for type SPR with built-in regulator.
Содержание SP 0
Страница 24: ...22 SP 0 SPR 0 6 Accessories 6 1 Wiring diagrams Wiring diagrams for EA SP 0 Wiring diagrams for EA SP 0 24 V DC...
Страница 27: ...SP 0 SPR 0 25...
Страница 28: ...26 SP 0 SPR 0...
Страница 29: ...SP 0 SPR 0 27...
Страница 30: ...28 SP 0 SPR 0...