982079 | 05 | 2021-03
17. Set Reactive Power
▷
Set the reactive power value.
18. Set Power Derating (active power reduction)
▷
Set active power reduction in %.
19. PE Line Control – 22. Set Election Meter
(Function not available.)
23. Logic Interface
▷
Activate or deactivate digital inputs.
24. DRMs0
(Function not available.)
25. Protocol (Modbus or REFU-USS)
▷
Switch between Modbus-9600N or REFU-USS-
57600E.
6.2.2 Main Menu > 2. Event List
The event list stores events in real time, with their
specific ID numbers and time of occurrence in
descending order.
1. Press the ESC key and the
∨
key until the menu dis
-
play shows "2. Event List".
2. Press the OK key to call up the total event list.
3. Press the OK key to display a single event ID number
with event time.
6.2.3 Main Menu > 3. System Info
The system information interface displays the unit
information and important settings.
Tab. 7:
RS485 interface settings REFU-USS
Parameter
Value
Baud rate
57600
Parity
even
Handshake
no
Data bits
8
Stop bit
1
Tab. 7: