the unit features an integral drain pump, drain line may go vertically up 18’prior to
reaching final drain location.
The quick connector into
the socket on the connector
Quick connection to draining tube
(
( 4 ) Set unit control as desired and energize.
3 ) Firmly insert power cord into socket on top back of unit.
a. Remove the inlet grille to access the filter
※
Maintenance and Repair
※
1. Exterior Cleaning
Use a soft, slightly damp cloth to wipe the plastic body.
2. Filter cleaning
REFINE-DEHUMIDIFIERS
-1
1
-
-1
0
-
REFINE-DEHUMIDIFIERS
Discharge Ducting
10.Handlebar Mounting
Handle rotates 180
°
, after aligning with locating pin holes will be fixed.
The locating pin is inserted and fixed
※
Preparing the Unit for Use
※
( 1 ) Position the machine for a minimum 8” clearance on back and sides. Front should
be positioned for maximum discharge distance or directly to specific location for spot drying.
If the unit was moved in such a manner that the compressor didn’t remain in a vertical
orientation, wait a minimum of 30 minutes before turning the unit“on.”
( 2 ) The included drain line attaches to the unit via a quick connection type fitting located
on the base of the unit.The drain line should be routed to a suitable drain or outside. Because