Refine Armored 70L Скачать руководство пользователя страница 5

-5

-

6. LCD monitor

When the unit is running, the LCD monitor will go dark if no buttons are pushed.  Push any 

button once to light monitor.

7. LCD display function

1

Show Power On when the machine has already connected but not started.

P o w e

o n

n

U n

i

t

 

O

2

Show UnitOn when the machine in working status(This display will disappear in 2 

seconds and then the next screen will appear.)

Use to confirm a selection.

4. Select/OK  Button

OK

These buttons are used for adjusting humidity or timer settings.  

5. UP Botton                Down Botton

Timer setting:

Timing for the start/Timing Shutdown/Cycle Timing

Temperature Scale Switch:

Degrees Celsius or Fahrenheit selection

Return:

Return to display the main page

NOTE:  See Section 8 for more detailed programming instructions.

3

The  LCD  interface  shows  two  lines  of  data.    The  first  line  displays  the  room 

temperature and humidity.  On the second line, Job T(working time) and Humidity Setpoint are 

displayed on an alternating basis.

I

n

l

e

t

 

3 2 ℃

7 6 %

The contents of the second line alternateevery 10 sec.

REFINE-DEHUMIDIFIERS

-4

-

Humidity Setting:Adjust the humidity setpoint

 ※

Operating instructions

Control Panel Operation

OK

M

P

Menu

up button

Down Button

LCD Monitor

On/Off

Select/OK

Drain Pump

1. ON/Off Button

Press this button, and the machine will start running. Press this key again and the machine 

will stop running.   The display will show room humidity levels except while you’re pressing 

another button.  NOTE:  When unit is turned off, the fan will run for 1 minute prior to shutting 

off.   In addition  the condensate  pump will pump for approximately  14 seconds  to drain  the 

pump reservoir after unit is powered off.

2. Pump Button

P

For  extended  storage  or  movement  of  the  machine,  press  the  “Pump”  bottom  to 

remove water from the integral pump’s reservoir.

3. Menu Button

M

Pressing  the  Menu  (M)  button,  gives  you  the  options  to  select  between  two  different 

control modes as well as adjust the temperature measurement units.  Continue pressing the M 

button  until  you  get  to  your  desired  selection.    Press  the  Select  (OK)  key  to  confirm  that 

selection and move to a submenu.

After  you’ve  completed  your  task  select“R”thenpress  the  select  (OK)  button  to 

moveback to Previous Menu, or wait for 10 S for automatically returning to main screen.

Four selections are available:

REFINE-DEHUMIDIFIERS

Содержание Armored 70L

Страница 1: ...midifiers com Installation and Operations Manual F E mail sales refine tec com Add NO 8 Mo gan shan Road Beilun Ningbo Zhejiang China P 86 574 55841701 86 574 55841702 DEHUMIDIFIERS Refine Dehumidifie...

Страница 2: ...if unit is already off press P button to confirm drain reservoir is empty After the pump has finished operation unplug the power cord and relocate unit to the desired position If the inside of the uni...

Страница 3: ...86 574 55841701 Customer Service For additional questions concerning the operation of your dehumidifier please Model Number Armored 70L Serial Number__________________________ Date of Purchase________...

Страница 4: ...ed back into the room Installation 120 Volts AC may cause serious injury from electric shock WARNING 1 Disconnect electrical power before servicing 2 Only plug unit into grounded electrical outlet 3 D...

Страница 5: ...4 Humidity Setting Adjust the humidity setpoint Operating instructions Control Panel Operation OK M P Menu up button Down Button LCD Monitor On Off Select OK DrainPump 1 ON Off Button Press this butto...

Страница 6: ...urn off You can also set up cycle timing which allows you to set up and repeating cycle of specific on and off durations a Press the menu key several times unit the Timer button is flashing Press OK b...

Страница 7: ...s T on T off T I 0 R H u m i d T i m e r T e m p U R T off Unit will stop when timer expires T I O Unit will cycle on and off based on the set time If unit is off the cycling will start with unit off...

Страница 8: ...EHUMIDIFIERS Discharge Ducting 10 Handlebar Mounting Handle rotates 180 after aligning with locating pin holes will be fixed The locating pin is inserted and fixed Preparing the Unit for Use 1 Positio...

Страница 9: ...be disconnected The pump can be removed from reservoir by using a flat screwdriver to gently pry pump assembly from reservoir Release these 4 Screws b Open the cover and remove the Electrical box cov...

Страница 10: ...ues from dirt and slime that may accumulate in the drain system including the drain pan hose to the condensate pump pump reservoir pump head and float assembly and discharge tubing At least once per y...

Страница 11: ...ther equipment or any other indirect or consequential damage with respect to property whether as a result of breach of warranty neglect or otherwise THE WARRANTIES AND LIABILITIES SET FORTH ARE IN LIE...

Страница 12: ...al liability of seller in the case of defective performanceof all or any of the equipment or services provided to Buyer Buyer agrees to accept and hereby accepts the foregoing as the sole and exclusiv...

Отзывы: