Installation
Selection of installation equipment
Cut out the work surface according to the sizes shown in the drawing.
For the purpose of installation and use, a minimum of 5 cm space shall be
preserved around the hole.
Be sure the thickness of the work surface is at least
30mm
. Please select
heat-resistant work surface material to avoid larger deformation caused by the
heat radiation from the hotplate. As shown below:
L(mm) W(mm) H(mm) D(mm) A(mm) B(mm) X(mm)
770
520
50
46
750
490
50 mini
Note: The safety distance between the hotplate and the cupboard above
the hotplate should be at least
760
mm.
Under all circumstances, make sure the ceramic
and the air inlet and outlet are not blocked. Ensure the ceramic
hob is well ventilated
hob is
in accordance with the instructions below.