Replacing the Collector Assembly (figure A)

1.  Remove access cover (1).
2.  Remove wire nuts (6) securing input electrical cord to collector 

assembly.

3.  Remove zip tie (not pictured), being careful to not damage wires.
4.  At terminal strip (2), disconnect wires (9) connecting brushes (12) 

to terminal strip.

5.  Remove lock nuts (10) securing brush holder (11) to reel. Relocate 

cable clamp temporarily and remove brush holder.

6.  Remove coupling nut (15).
7.  Remove collector assembly.
8.  Install replacement collector assembly by reversing steps 1 

through 5. Upon completion of installation, adjust brush-to-ring 
alignment by loosening nuts (13) and sliding finger assembly 
(14).

9.  Replace access cover (1).

Troubleshooting Instructions (figure A)

Troubleshooting of the reel consists of isolating a problem to a defec-
tive electrical cord/work device, brush holder/brushes, or collector 
assembly. Refer any other discrepancies only to an authorized service 
person or directly to Reelcraft.

WARNING:

The following procedure directs the technician to take voltage mea-
surements. Remember, even low voltage is dangerous and can cause 
personal injury or death. Exercise extreme caution! Ensure that only a 
qualified electrican installs or services this equipment.
1.  If work device is either an incandescent or fluorescent light, 

replace bulb with a known good bulb. If this does not correct the 
problem, proceed to step 2. If work device is an electrical recept-
able, ensure that tool or fixture connected to it is in good working 
order. If it is, proceed to step 2.

2.  Remove power from reel.
3.  Remove access cover (1).
4.  Reapply power to reel.
5.  Check for correct voltage (120 vac) at a terminal strip (2). If volt-

age reading is correct, replace output electrical device (refer to 
page 3). If voltage reading is incorrect, proceed to step 6.

6.  Remove power from reel.
7.  Using ohmmeter, check continuity of input electrical cord. If cord 

checks good, proceed to step 8. If cord is faulty, replace it (refer to 
page 3). Remove brush holder/brushes from reel and inspect (refer 
to page 3). Replace defective components then proceed to step 9.

8.  Reapply power to reel.
9.  Check for correct voltage (120 vac) at terminal strip (2). 
10.  If voltage reading is still incorrect, replace defective collector 

assembly (refer to page 4).

11.  Replace access cover (1).

Service Instructions 

Maintain reel by following the service instructions given in this manual. 
Refer all other repairs, other than those listed, only to an authorized 
service person or directly to Reelcraft. Failure to do so can result in 
personal injury and/or equipment damage and may void the warranty.