10. IMPORTANT re SAFETY SWITCH (RCD);

(a) The Pump must be connected to a suitable power circuit protected by a RCD (safety switch) having a rated residual operating current 

not exceeding 30mA, in the circuit breaker. (3-Phase 415 Volt Pumps must be installed by a licenced Electrician according to applicable 

Regulations & Australian Standards) Disconnect the pump from power supply when people are in the water, or when servicing or repairing 

the pump. All warranty is void if this instruction is not followed. Plugging into existing outlets may cause low voltage supply to the motor, 

which may trip motor overload, or burn out the motor, which will not be covered by the Warranty.

(b) Surge Protection - We recommend that a surge protector is used to protect the electronics of this pump, as damage due to power 

surges is not covered by the Warranty.

11. MAINS PRESSURE BOOSTING 

This is a specialized type of application, and must be completed by a Qualified Plumber or Pump 

Technician who is competent and licenced to perform this type of installation.

12. VOLTAGE

 of power supply must match the voltage of the pump – 240V AC only for Single-Phase pumps, 415V for 3-Phase pumps, 

refer to the nameplate of the pump for correct voltage. Do not run on generator power from low quality/old generators. If you only have 

generator power, you may need to have the Pressure Controller removed and replaced with a Pressure Tank and Switch, at additional cost. 

The Pressure Controller will be damaged by the voltage fluctuations caused by power supplied by low quality generators. High quality 

“Sine-Wave” generators are usually acceptable but we cannot guarantee this, as we have no control over the generator that you use, it is 

your responsibility to ensure the generator used is fit for the purpose.

13.

 WARNING: 

these pumps are not designed for, and must not be installed in locations classified as hazardous.

14. THE FOLLOWING MAY CAUSE SEVERE DAMAGE TO THE PUMP AND WILL VOID WARRANTY;

(a) Using an extension cord to power the pump.

(b) Cutting the earth pin off the plug or using an adapter fitting or double adapter.

(c) Working on the pump while connected to the power supply.

(d) Removing motor housing, or dissembling the pump housing, except by a qualified technician

(e) Pumping chemicals or corrosive liquids or flammable liquids.

(f) Pumping hot liquids (Exceeding 40° Centigrade)

(g) Using a generator for power supply - see 12

(h) Operations that involve frequent starting. This will lead to premature failure of the capacitor. We recommend that if the pump is 

regularly starting more often than 10 times per hour, you should add a 18L or larger pressure tank into the system. Occasional frequent 

starting (for example during the evening showers) is not a problem, but constant (most of the day) frequent starting is a problem. Note 

that if the pump starts and stops more than 7 times within 2 minutes, it may switch itself off and you will need to press the restart button 

to reactivate it.

15.PUMP PRIMING AND START UP

(a) Dry operation will destroy the pump seals and is not covered by warranty.

(b) Remove the pressure controller by loosening the barrel union, (or use the priming plug at the front of the wet-end, near the inlet, but 

that is slower) and completely fill the pump chamber with water before starting.

(c) Turn the pump on, if water does not flow, turn it off and repeat step 15(b) again, and if it is suction-lift the entire suction pipe may need 

to be pre-primed.

(d) If it still does not pump water, check the intake and discharge pipework is free from airlocks, or any other obstructions and refer to the 

TROUBLESHOOTING guide.

16. SUCTION LIFT

Suction lift installations are notoriously troublesome, and almost invariably it is not the pump that causes the problem, we recommend 

using a submersible pump system if at all possible.

WARNING! 

Multistage pumps are not recommended to be used in suction lift applications. Contact REEFE Pumps technicians on 1800 807 

604 if you have any questions in relation to suction lift installation. 

17. OVERLOAD PROTECTION

This pump has a built in thermal protection switch. The pump stops if a high-temperature condition occurs. The motor restarts 

automatically after it has cooled down when the built in thermal protector resets itself. Or you may need to turn the power off and on 

again to reset it. If this problem reoccurs - check as per 15

18. IMPORTANT NOTES

(a) Do not switch the pump on and off frequently, as this will cause damage to the electronics and void warranty. (b) Do not attempt to 

adjust the flow via the intake pipework (c) If there is insufficient water, the motor will stop. See 15 (f) and also 19.  (d) If the  pump is idle 

for a long period of time or in very low temperature, the water should be drained to avoid damage to the pump and/or stagnation of 

water.

DANGER!

Keep the pump equipment protected from interference by pets, wildlife, children, infirm persons or incompetent persons.

WARNING!

This pump is designed for clean fresh water only, in non-hazardous locations. It must NOT be used as a continuous duty fountain pump, or 

dirty water, or liquids other than water. Install in well ventilated and well drained area.

19. PUMP CONTROLLER FUNCTION AND OPERATION:

The Pump Controller (sometimes referred to as the Pressure Controller) fitted to this pump is designed to be almost completely automatic, 

and will restart itself if the pump runs out of water; you should not normally need to do anything. Instructions and basic function;

a) Use for CLEAN rainwater only – you must fit a prefilter or Y-Strainer to the intake (suction pipe) of the pump

b) Do not use a low quality generator for power supply - see section 12 - as this may damage the electronics

c) Protect from direct sunlight to avoid UV damage to the plastic

d) The pump controller will stop the pump if there is no water in the pump

e) It then immediately rechecks for water (Starts pump) for a 15 second trial. Then rechecks again at the 3 minute mark, 1 hour mark, 5 

hour mark and then every 24 hours after until the pump reprimes. 

f) When the pump is connected to a rain water tank, once the tank refills with water, the pump automatically reprimes and starts to supply.

g) If it happens to do this in the middle of the night it can be annoying! In the morning, turn it off & on again after 30 seconds and it will 

reset itself so it does the checking in daylight hours.

h) Leak detection function: if the pump starts and stops 7 times or more in about 2 minutes, the pump may turn off automatically. If this 

occurs, investigate what is leaking.

VSRE - Parts Breakdown.indd   8

VSRE - Parts Breakdown.indd   8

25/06/2021   1:32:52 PM

25/06/2021   1:32:52 PM

Содержание 21620

Страница 1: ... BETTER FASTER EASIER BETTER FASTER EASIER VARIABLE SPEED MULTISTAGE PUMP MODELS VSRE40 60 38 110 52 110 67 120 50 175 65 175 46 350 CODE 21620 21637 21644 21651 21668 21675 21682 VSRE Parts Breakdown indd 1 VSRE Parts Breakdown indd 1 25 06 2021 1 32 49 PM 25 06 2021 1 32 49 PM ...

Страница 2: ...ss Steel 13 Diffuser Lid Welded Noryl 14 Diffuser Cover Noryl 15 Pump Body Stainless Steel www oliju com 43 SURFACE PRESSURE CHS POS COMPONENT MATERIALS 1 Stator on Casing 2 Capacitor 3 Rotor Shaft Steel and Aluminium Stainless Steel 4 Bearing Steel 5 Bearing Steel 6 Cover Aluminium 7 Intercalate Aluminium 8 Disc Stainless Steel 9 ΖQLWLDO L XVHU Noryl 10 Mechanical Seal Fixe Nitrile Rubber Ceramic...

Страница 3: ...OUT BARREL UNION S A Y STRAINER A BALL VALVE W R O N G DIAGRAM 3 DIAGRAM 4 TIP CLEAN THE Y STRAINER MONTHLY TO ENSURE PEAK PERFORMANCE SIMPLY UNDO THE BUNG AND LET IT FLUSH OUT MAKE SURE YOU RE FIT THE MESH FILTER TIP IF PUMP STARTS FREQUENTLY CHECK TOILET CISTERNS THEY ARE PROBABLY LEAKING PRESSURE TANKS CAN SAVE YOU MONEY AS THE PUMP DOES NOT HAVE TO START SO OFTEN TIP IMPORTANT MULTISTAGE PUMPS...

Страница 4: ...P IS ABOVE THE OUTLET OF THE TANK ALWAYS USE A FOOT VALVE IN THE TANK W R O N G DIAGRAM 7 DIAGRAM 8 W R O N G INCORRECT PUMP IS NOT INSTALLED ON A LEVEL SURFACE ALWAYS ENSURE THE PUMP IS INSTALLED LEVEL INCORRECT THE PUMP IS CONNECTED INCORRECTLY ALWAYS ENSURE WATER INLET AND OUTLET ARE CORRECT W R O N G W R O N G DIAGRAM 5 DIAGRAM 6 IMPORTANT IMPORTANT MULTISTAGE PUMPS MUST NOT BE USED WITH SUCTI...

Страница 5: ... SUCTION INTAKE PIPEWORK IT IS CRITICAL THAT THE CORRECT PIPE SIZE IS USED ESPECIALLY IN SUCTION LIFT APPLICATIONS CHECK WITH A QUALIFIED PUMP TECHNICIAN FOR THIS TYPE OF INSTALLATION INCORRECT PIPES TOO SMALL FOR PUMP INLET USE 25mm PIPE INTERNAL DIAMETER WE RECOMMEND 30mm FOR BEST PERFORMANCE FOR PUMPS WITH 32MM INTAKE OR LARGER USE SUCTION PIPE ONE OR MORE SIZE LARGER For the oulet discharge pi...

Страница 6: ...UMP DIRECTLY TO THE ELEMENTS WE RECOMMEND THE PUMP IS PROTECTED WITH A PUMP COVER IMPORTANT CONSIDER NEIGHBOURS WHEN INSTALLING THE PUMP ALL PUMPS MAKE SOME NOISE IMPORTANT ENSURE THE PUMP IS SIZED CORRECTLY FOR THE JOB TOO SMALL LOW PERFORMANCE AND MAY USE EXCESS POWER AND OR OVERHEAT THE MOTOR AND OR CAUSE PREMATURE FAILURE THIS IS NOT A WARRANTY FAULT IF THIS OCCURS DIAGRAM 12 DIAGRAM 13 DIAGRA...

Страница 7: ...y of a plastic pump cover or skillion roof cover or similar However the installer must ensure that there is adequate ventilation so the pump does not overheat 4 IMPORTANT re INSTALLATION This pump MUST NOT be installed in any manner that if it were to leak that it would cause damage or loss to property or persons It MUST be installed in a well ventilated and drained area All warranty is void if th...

Страница 8: ... wet end near the inlet but that is slower and completely fill the pump chamber with water before starting c Turn the pump on if water does not flow turn it off and repeat step 15 b again and if it is suction lift the entire suction pipe may need to be pre primed d If it still does not pump water check the intake and discharge pipework is free from airlocks or any other obstructions and refer to t...

Страница 9: ...ter might be blocked flush clean and re assemble if it is the pump disconnect from the power supply and if you are competent to do so disassemble the pump and clean If not have a pump technician do it for you 4 Pump is air locked Start and stop several times by turning it on and off with 20 seconds between If this does not work see below regarding re priming the pump 5 Vertical pumping distance is...

Страница 10: ...ropriate purpose for which it is intended according to the instructions The Power Circuit the Pump is connected to is RCD Safety Switch Protected A Y Strainer or Pre filter is installed in the suction pipe to prevent particles entering the pump All swarf has been removed from the tank after cutting openings etc Barrel Unions are fitted on the pipe connections for easy removal replacement A Ball Va...