APPLICATION: CONSTANT PRESSURE PUMPS are fit for purpose when installed correctly according to these instructions;

For pumping of Clean Fresh Water at a temperature of +5°C to +40°C to: Garden Taps, Houses, Sheds, Cabins, Pressure Boosting, 

Clean Water Transfer, suitable Rain-to-Mains Systems (370Watt and greater motor size) and for no other use. They must not be used in 

hazardous locations or for liquids other than clean water, or for continuous operation.

DANGER: DO NOT INSTALL ANY PUMP if the premises does not have a Safety Switch (RCD)

IMPORTANT: 

Ensure the pump is the right size for your application, before you install it. A pump that is under-sized is not  faulty, and is 

not covered by warranty. Ensure the right size piping is used, small pipes reduce performance and cause the pump to use more power! 

See below for further information, and refer to the information on the box and/or label on the pump for the performance data. If in doubt 

consult with your dealer or a pump technician to ensure your pump is sized to suit your needs.

PERFORMANCE DATA

Refer to the information on the box.

NOTES: Performance data quoted is generally from test data, and can vary, and does not take into account factors in the installation such 

as loss of pressure and flow due to pipework & pipe-fittings & valves. Product depicted on the box and referred to in this document, and 

other diagrammatic instructions, may differ from the product supplied, due to design changes or improvements.

***Be aware that the Amps and Wattage will vary according to the load on the motor, the figures stated are approximate.

INSTALLATION GUIDELINES

Please read and follow the instructions including the diagrammatic instructions. Warranty is voided if the instructions are not followed.

1a.

 

IMPORTANT MANDATORY REQUIREMENTS FOR ALL INSTALLATIONS:

 

Before installing or servicing disconnect from the power supply. 

All pumps must be installed using barrel-union connections to facilitate easy servicing or replacement. Ball-valves or gate- valves must be 

fitted on the suction, and the discharge, and the Town-water backup supply where fitted. A Y-Strainer or Pre-filter must be installed on 

the suction to prevent particles entering the pump. Remove all swarf from the tank after cutting openings etc – swarf in the pump voids 

warranty. All instructions are conditions of warranty; all warranty is void if instructions are not followed.

It is recommended to install a Check-Valve in the discharge pipework, however DO NOT install the check valve directly on the discharge 

of the Pressure Controller, as this may cause it to malfunction, install the Check-Valve further down the pipe, before the first point of 

discharge.

1b.

 

IRRIGATION USE - MANDATORY REQUIREMENTS FOR ALL INSTALLATIONS: 

For any installation of these pumps  that  is supplying 

irrigation, you must fit an 18L or larger pressure tank. Air pressure must be set at 70% of maximum pump pressure.  Tank is simply fitted to 

the discharge pipework with a “tee”, anywhere between the pump and the first point of discharge.

2. POSITION

 Do not position the pump where it could take in solids or sludge. This pump is not to be used as your sole water supply. For 

critical applications where loss of water supply could cause serious consequences, use a DUAL PUMP System so you have a second water 

supply or use a TOWN-WATER BACK-UP SYSTEM. This pump is not designed for Fire Fighting purposes.

3. PROTECT FROM THE WEATHER:

 The pump must be protected from the weather, by way of a plastic pump cover or skillion roof cover, 

or similar. However the installer must ensure that there is adequate ventilation so the pump does not overheat.

4. IMPORTANT re INSTALLATION:

 This pump MUST NOT be installed in any manner that if it were to leak that it would cause damage or 

loss to property or persons. It MUST be installed in a well-ventilated and drained area. All warranty is void if this condition is not heeded 

and no liability can be accepted in the case of damage or loss caused by failing to comply with this  condition. If the pump leaks, the water 

must be able to drain away from the pump and not cause damage.

DANGER! 

If water pools around the pump (from any source of water) it will cause a dangerous electrical hazard.

5. BASE must be LEVEL

 Fix the pump in place through the footplate using suitable fasteners, on a stable, level surface – the base must 

NOT be sloping even slightly – ensure it is level.

6. IMPORTANT NOTE re PUMP NOISE: 

Avoid installing pumps near bedrooms or neighbours bedrooms. Particularly JET pumps, due to 

their self-priming design they typically make more noise than a MULTISTAGE Pump. This is a feature of the pump design, it is not a fault, 

and is not a cause for warranty claims, as it is not a product fault. If noise is likely to cause problems, we recommend that you use a 

MULTISTAGE Pump, and install the pump AWAY from bedrooms.

7. (a) PIPE SIZE AND TYPE: 

Install the pump as near the water supply as possible to reduce the length of suction pipe. We recommend 

heavy duty flexible suction hose for the inlet (Suction Pipe) but whatever pipe is used it must be no less than the same Internal Diameter 

as the PUMP INLET (1 size bigger is better), and heavy-duty pressure hose or similar for the outlet, we  recommend the Internal Diameter 

for the delivery pipework is the same as the PUMP OUTLET for the best performance, or no more than one size less than the Pump Outlet 

Internal Diameter. If the pump is for “Whole of house” supply (check is your pump big enough first!!) we strongly recommend that 25mm 

Internal Diameter piping is used throughout the house, and is only reduced to connect to the fixtures as required, this will ensure that 

the pump delivers best performance and efficiency, saving the user money over the long-term. Use as few bends as possible, every bend 

reduces performance.

IMPORTANT! 

If your house has more than 3 bathrooms you MUST consult with a Pump Specialist to ensure you size your Pump and 

Pipework correctly – remember that a short term saving could become a long-term liability.

7. (b) MORE INFO RE PIPE SIZE:

 Pressure of the water at the discharge (taps, showers, irrigation etc) is affected by the pipe size.  The 

SMALLER your pipes, the LOWER the pressure will be at discharge. Example: 13mm ID pipe over 20 metres at 30Lpm will reduce pressure 

at discharge by 240kPa (2.4bar) - whereas if 25mm ID pipe is used for 20 meters at 30Lpm it only reduces pressure by a miniscule 10kPa. 

Smaller pipe also means that more power will be used as the pump has to work harder to overcome the extra back-pressure from small 

pipes. A small short-term saving (in the cost of the pipes) will become a long-term liability.

8. SEAL JOINTS 

Ensure all fittings and joints are watertight and airtight, especially in suction-lift applications.

9. INSTALLATION AND ELECTRICAL WIRING

 must adhere to state and local codes and must be completed before priming the pump. 

These pumps come with an earthed power plug and all electrical installations must be earthed. Any Electrical work must be performed by 

a licenced Electrician. The installation must also comply with applicable Plumbing Regulations, it is the installers responsibility to ensure 

compliance.

VSRE - Parts Breakdown.indd   7

VSRE - Parts Breakdown.indd   7

25/06/2021   1:32:52 PM

25/06/2021   1:32:52 PM

Содержание 21620

Страница 1: ... BETTER FASTER EASIER BETTER FASTER EASIER VARIABLE SPEED MULTISTAGE PUMP MODELS VSRE40 60 38 110 52 110 67 120 50 175 65 175 46 350 CODE 21620 21637 21644 21651 21668 21675 21682 VSRE Parts Breakdown indd 1 VSRE Parts Breakdown indd 1 25 06 2021 1 32 49 PM 25 06 2021 1 32 49 PM ...

Страница 2: ...ss Steel 13 Diffuser Lid Welded Noryl 14 Diffuser Cover Noryl 15 Pump Body Stainless Steel www oliju com 43 SURFACE PRESSURE CHS POS COMPONENT MATERIALS 1 Stator on Casing 2 Capacitor 3 Rotor Shaft Steel and Aluminium Stainless Steel 4 Bearing Steel 5 Bearing Steel 6 Cover Aluminium 7 Intercalate Aluminium 8 Disc Stainless Steel 9 ΖQLWLDO L XVHU Noryl 10 Mechanical Seal Fixe Nitrile Rubber Ceramic...

Страница 3: ...OUT BARREL UNION S A Y STRAINER A BALL VALVE W R O N G DIAGRAM 3 DIAGRAM 4 TIP CLEAN THE Y STRAINER MONTHLY TO ENSURE PEAK PERFORMANCE SIMPLY UNDO THE BUNG AND LET IT FLUSH OUT MAKE SURE YOU RE FIT THE MESH FILTER TIP IF PUMP STARTS FREQUENTLY CHECK TOILET CISTERNS THEY ARE PROBABLY LEAKING PRESSURE TANKS CAN SAVE YOU MONEY AS THE PUMP DOES NOT HAVE TO START SO OFTEN TIP IMPORTANT MULTISTAGE PUMPS...

Страница 4: ...P IS ABOVE THE OUTLET OF THE TANK ALWAYS USE A FOOT VALVE IN THE TANK W R O N G DIAGRAM 7 DIAGRAM 8 W R O N G INCORRECT PUMP IS NOT INSTALLED ON A LEVEL SURFACE ALWAYS ENSURE THE PUMP IS INSTALLED LEVEL INCORRECT THE PUMP IS CONNECTED INCORRECTLY ALWAYS ENSURE WATER INLET AND OUTLET ARE CORRECT W R O N G W R O N G DIAGRAM 5 DIAGRAM 6 IMPORTANT IMPORTANT MULTISTAGE PUMPS MUST NOT BE USED WITH SUCTI...

Страница 5: ... SUCTION INTAKE PIPEWORK IT IS CRITICAL THAT THE CORRECT PIPE SIZE IS USED ESPECIALLY IN SUCTION LIFT APPLICATIONS CHECK WITH A QUALIFIED PUMP TECHNICIAN FOR THIS TYPE OF INSTALLATION INCORRECT PIPES TOO SMALL FOR PUMP INLET USE 25mm PIPE INTERNAL DIAMETER WE RECOMMEND 30mm FOR BEST PERFORMANCE FOR PUMPS WITH 32MM INTAKE OR LARGER USE SUCTION PIPE ONE OR MORE SIZE LARGER For the oulet discharge pi...

Страница 6: ...UMP DIRECTLY TO THE ELEMENTS WE RECOMMEND THE PUMP IS PROTECTED WITH A PUMP COVER IMPORTANT CONSIDER NEIGHBOURS WHEN INSTALLING THE PUMP ALL PUMPS MAKE SOME NOISE IMPORTANT ENSURE THE PUMP IS SIZED CORRECTLY FOR THE JOB TOO SMALL LOW PERFORMANCE AND MAY USE EXCESS POWER AND OR OVERHEAT THE MOTOR AND OR CAUSE PREMATURE FAILURE THIS IS NOT A WARRANTY FAULT IF THIS OCCURS DIAGRAM 12 DIAGRAM 13 DIAGRA...

Страница 7: ...y of a plastic pump cover or skillion roof cover or similar However the installer must ensure that there is adequate ventilation so the pump does not overheat 4 IMPORTANT re INSTALLATION This pump MUST NOT be installed in any manner that if it were to leak that it would cause damage or loss to property or persons It MUST be installed in a well ventilated and drained area All warranty is void if th...

Страница 8: ... wet end near the inlet but that is slower and completely fill the pump chamber with water before starting c Turn the pump on if water does not flow turn it off and repeat step 15 b again and if it is suction lift the entire suction pipe may need to be pre primed d If it still does not pump water check the intake and discharge pipework is free from airlocks or any other obstructions and refer to t...

Страница 9: ...ter might be blocked flush clean and re assemble if it is the pump disconnect from the power supply and if you are competent to do so disassemble the pump and clean If not have a pump technician do it for you 4 Pump is air locked Start and stop several times by turning it on and off with 20 seconds between If this does not work see below regarding re priming the pump 5 Vertical pumping distance is...

Страница 10: ...ropriate purpose for which it is intended according to the instructions The Power Circuit the Pump is connected to is RCD Safety Switch Protected A Y Strainer or Pre filter is installed in the suction pipe to prevent particles entering the pump All swarf has been removed from the tank after cutting openings etc Barrel Unions are fitted on the pipe connections for easy removal replacement A Ball Va...