Reefe 21620 Скачать руководство пользователя страница 10

www.

reefe

.com.au

Ascento Group Australia

© 

AI.062020

P: 1800 807 604

WARNING!

ELECTRICAL PRECAUTIONS

DO NOT INSTALL PUMP if the premises does not have a Safety Switch (RCD)

Before servicing a pump, always shut off the power supply and then make sure you are not standing in water and that there 

is no risk of electrical shock. If pump is direct-wired to the electrical circuit, have a qualified licensed electrician disconnect it 

before attempting any repairs or servicing.

DO NOT ATTEMPT ELECTRICAL REPAIRS OF ANY SORT UNLESS YOU ARE A LICENSED 

ELECTRICIAN

WARRANTY RECORD - FILL IN AND RETAIN THIS WITH YOUR ORIGINAL PURCHASE RECEIPT

PURCHASER NAME & ADDRESS...................................................................................... PHONE NO...............................

DATE OF PURCHASE ………../.........../............ DEALER/STORE NAME..............…................................…............................

DEALER SUBURB/TOWN….....…...............…........................................................... PHONE NO…......................................

BRAND & MODEL NUMBER OF PUMP……...................................... BATCH or SERIAL NUMBER…………………………………..

Do NOT send this form to us, retain it for your record.

INSTALLATION CHECKLIST: MUST BE FILLED IN FOR WARRANTY TO APPLY

Installer Name__________________________Qualification:__________________________(write Owner if applicable) 

Phone Number: ____________________If installed by a Plumber or Electrician, Licence No:_____________________   

Installation Address:_____________________________________________________________________________  

    

Tick the boxes as the item is completed/correct, put n/a if not applicable;

] The Pump is being used for an appropriate purpose for which it is intended, according to the instructions 

] The Power Circuit the Pump is connected to is RCD (Safety Switch) Protected

] A Y-Strainer or Pre-filter is installed in the suction pipe to prevent particles entering the pump 

] All swarf has been removed from the tank after cutting openings etc.

] Barrel Unions are fitted on the pipe connections for easy removal & replacement

] A Ball Valve or Gate Valve is fitted to the suction pipe (the pipe from tank to pump) 

] Pipe is sized appropriately for the application (diameter and length)

] The installation is constructed so the pump can be easily removed or replaced.  

] The pump is installed in accordance with National & Local Plumbing Regulations

] The Electrical Supply cable is plugged into a Power Outlet that is in accordance with the current standard    

 

of  Electrical Safety Regulations AS/NZS 3000 – or the pump has been wired directly to the power circuit by a  

 

Licenced Electrician.

] The Pump has been primed (filled with water) started, tested, and operates correctly.

] The pipes and connections and the barrel-union on the pump, and toilet cisterns (if connected) have been checked  

 

for leaks. 

] The pump is protected from sunlight & rain, with a suitable vented pump-cover or enclosure.

] The Owner has been shown how to re-prime and re-set the pump (re-fill the pump with water if it runs dry)

Signed by the Installer:________________________________________  Date Installed:         /     /  

VSRE - Parts Breakdown.indd   10

VSRE - Parts Breakdown.indd   10

25/06/2021   1:32:52 PM

25/06/2021   1:32:52 PM

Содержание 21620

Страница 1: ... BETTER FASTER EASIER BETTER FASTER EASIER VARIABLE SPEED MULTISTAGE PUMP MODELS VSRE40 60 38 110 52 110 67 120 50 175 65 175 46 350 CODE 21620 21637 21644 21651 21668 21675 21682 VSRE Parts Breakdown indd 1 VSRE Parts Breakdown indd 1 25 06 2021 1 32 49 PM 25 06 2021 1 32 49 PM ...

Страница 2: ...ss Steel 13 Diffuser Lid Welded Noryl 14 Diffuser Cover Noryl 15 Pump Body Stainless Steel www oliju com 43 SURFACE PRESSURE CHS POS COMPONENT MATERIALS 1 Stator on Casing 2 Capacitor 3 Rotor Shaft Steel and Aluminium Stainless Steel 4 Bearing Steel 5 Bearing Steel 6 Cover Aluminium 7 Intercalate Aluminium 8 Disc Stainless Steel 9 ΖQLWLDO L XVHU Noryl 10 Mechanical Seal Fixe Nitrile Rubber Ceramic...

Страница 3: ...OUT BARREL UNION S A Y STRAINER A BALL VALVE W R O N G DIAGRAM 3 DIAGRAM 4 TIP CLEAN THE Y STRAINER MONTHLY TO ENSURE PEAK PERFORMANCE SIMPLY UNDO THE BUNG AND LET IT FLUSH OUT MAKE SURE YOU RE FIT THE MESH FILTER TIP IF PUMP STARTS FREQUENTLY CHECK TOILET CISTERNS THEY ARE PROBABLY LEAKING PRESSURE TANKS CAN SAVE YOU MONEY AS THE PUMP DOES NOT HAVE TO START SO OFTEN TIP IMPORTANT MULTISTAGE PUMPS...

Страница 4: ...P IS ABOVE THE OUTLET OF THE TANK ALWAYS USE A FOOT VALVE IN THE TANK W R O N G DIAGRAM 7 DIAGRAM 8 W R O N G INCORRECT PUMP IS NOT INSTALLED ON A LEVEL SURFACE ALWAYS ENSURE THE PUMP IS INSTALLED LEVEL INCORRECT THE PUMP IS CONNECTED INCORRECTLY ALWAYS ENSURE WATER INLET AND OUTLET ARE CORRECT W R O N G W R O N G DIAGRAM 5 DIAGRAM 6 IMPORTANT IMPORTANT MULTISTAGE PUMPS MUST NOT BE USED WITH SUCTI...

Страница 5: ... SUCTION INTAKE PIPEWORK IT IS CRITICAL THAT THE CORRECT PIPE SIZE IS USED ESPECIALLY IN SUCTION LIFT APPLICATIONS CHECK WITH A QUALIFIED PUMP TECHNICIAN FOR THIS TYPE OF INSTALLATION INCORRECT PIPES TOO SMALL FOR PUMP INLET USE 25mm PIPE INTERNAL DIAMETER WE RECOMMEND 30mm FOR BEST PERFORMANCE FOR PUMPS WITH 32MM INTAKE OR LARGER USE SUCTION PIPE ONE OR MORE SIZE LARGER For the oulet discharge pi...

Страница 6: ...UMP DIRECTLY TO THE ELEMENTS WE RECOMMEND THE PUMP IS PROTECTED WITH A PUMP COVER IMPORTANT CONSIDER NEIGHBOURS WHEN INSTALLING THE PUMP ALL PUMPS MAKE SOME NOISE IMPORTANT ENSURE THE PUMP IS SIZED CORRECTLY FOR THE JOB TOO SMALL LOW PERFORMANCE AND MAY USE EXCESS POWER AND OR OVERHEAT THE MOTOR AND OR CAUSE PREMATURE FAILURE THIS IS NOT A WARRANTY FAULT IF THIS OCCURS DIAGRAM 12 DIAGRAM 13 DIAGRA...

Страница 7: ...y of a plastic pump cover or skillion roof cover or similar However the installer must ensure that there is adequate ventilation so the pump does not overheat 4 IMPORTANT re INSTALLATION This pump MUST NOT be installed in any manner that if it were to leak that it would cause damage or loss to property or persons It MUST be installed in a well ventilated and drained area All warranty is void if th...

Страница 8: ... wet end near the inlet but that is slower and completely fill the pump chamber with water before starting c Turn the pump on if water does not flow turn it off and repeat step 15 b again and if it is suction lift the entire suction pipe may need to be pre primed d If it still does not pump water check the intake and discharge pipework is free from airlocks or any other obstructions and refer to t...

Страница 9: ...ter might be blocked flush clean and re assemble if it is the pump disconnect from the power supply and if you are competent to do so disassemble the pump and clean If not have a pump technician do it for you 4 Pump is air locked Start and stop several times by turning it on and off with 20 seconds between If this does not work see below regarding re priming the pump 5 Vertical pumping distance is...

Страница 10: ...ropriate purpose for which it is intended according to the instructions The Power Circuit the Pump is connected to is RCD Safety Switch Protected A Y Strainer or Pre filter is installed in the suction pipe to prevent particles entering the pump All swarf has been removed from the tank after cutting openings etc Barrel Unions are fitted on the pipe connections for easy removal replacement A Ball Va...

Отзывы: