reedinstruments
www
com
7
Capacitance (Auto-ranging)
Range
Resolution
accuracy
40.00nF
10pF
±5.0% of rdg + 7 dgts
400.0nF
0.1nF
±3.5% of rdg + 5 dgts
4.000uF
1nF
40.00uF
10nF
100.0uF
0.1uF
±5.0% of rdg + 5 dgts
Input Protection: 500V DC or 500V AC RMS.
Frequency (Auto-ranging)
Range
Resolution
accuracy
Sensitivity
9.999kHz
0.001Hz
±1.2% of rdg + 5 dgts
0.5V RMS min.
99.99kHz
0.01Hz
999.9kHz
0.1Hz
±1.2% of rdg + 3 dgts
9.999kHz
1Hz
99.99kHz
10Hz
0.8V RMS min.
999.9kHz
100Hz
3.5V RMS min.
9.999kHz
1kHz
±1.5% of rdg + 4 dgts 8.0V RMS min.
Sensitivity: RMS min. at >20% and <80% duty cycle
Sensitivity: More than 100 digits at pulse width >2uSec.
Overload Protection: 500V DC or AC RMS.
Duty Cycle
Range
Resolution
accuracy
0.1% to 99.9%
0.1%
±1.2% of rdg ± 2 digits
Frequency: 1 Hz to 150 Hz
Sensitivity: 0.5 V RMS min. when F < 10 kHz; 0.8 V RMS min.
when F > 10 kHz; <100 kHz; 3.5 V RMS min.
when F > 100 kHz; < 150 kHz
Pulse Width: > 100 us, < 100 ms
Overload Protection: 500V DC or AC RMS.