Input Jacks
This meter has four input jacks that are protected against overload to the
limits of 20A. During use, connect the Black test lead to the COM jack and
the Red test lead as shown below:
Function
Red lead Connection
input limits
DCV/ACV
“+”
1000V DC or 750 AC RMS
Ω
“+”
500V DC or AC RMS
CONTINUITY/DIODE
“+”
500V DC or AC RMS
CAP
“+”
500V DC or AC RMS
Hz/%
“+”
500V DC or AC RMS
uA/mA
“+”
400mA DC or AC RMS
A
10A
10A DC or AC RMS
TEMP.
Temp. jack
60V DC or 24 AC RMS
Voltage Measurement
1. Insert the black test lead into the negative COM terminal and the red
test lead into the positive V terminal.
2. Set the function switch to the DCV or ACV position.
3. Connect the test leads to the source or load being measured.
4. Read the voltage measurement on the LCD display. The polarity of the
Red connection will be indicated when making a DC measurement.
Current Measurement
1. Insert the black test lead into the negative (COM) terminal and the red
test lead into the positive (μA, mA) terminal for a maximum measure
-
ment of 400mA. For a maximum measurement of 10A, move the red
test lead to the positive (A) terminal.
2. Set the function switch to the μA, mA or A position and press the DC/AC
button to select the DCA or ACA measurement mode.
3. Connect the test leads to the source or load being measured.
4. Read the voltage measurement on the LCD display. The polarity of the
Red connection will be indicated when making a DC measurement.