reedinstruments
www
com
8
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black
Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Continuity Test
1. Insert the black test lead into the negative COM terminal and the
red test lead into the positive V diode terminal.
2. Press the MODE button until the “Continuity indicator” appears on
the display.
3. Touch the test probe tips across the circuit or component under
test. If the resistance is < 35Ω, a tone will sound.
Diode Test
1. Insert the black test lead into the negative COM terminal and the
red test lead into the positive V diode terminal.
2. Press the MODE button until the “Diode Test indicator” appears
on the display.
3. Touch the test probe tips to the diode or semiconductor junction
under test. Note the meter reading.
4. The diode or junction can be evaluated as follows:
• If one reading displays a value (typically 0.400V to 01.800V)
and the other reading displays OL, the diode is good.
• If both readings display OL the device is open.
• If both readings are very small or ‘0’, the device is shorted.
Capacitance Measurements
1. To avoid electric shock, disconnect power to the unit under test
and discharge all capacitors before taking any capacitance mea-
surements. Remove the batteries and unplug the line cords.
2. Set the rotary function switch to the CAP position.
3. Press the MODE button until CAP is indicated on the display.
4. Insert the black test lead into the negative COM terminal and the
red test lead into the positive V terminal.
5. Touch the test leads to the capacitor to be tested. Read the
capacitance value on the display.
www.
GlobalTestSupply
.com
Find Quality Products Online at: