Safety

• 

Do not exceed the maximum allowable input range of any function

• 

Do not apply voltage to the meter when resistance function  
is selected

• 

Set the function switch OFF when the meter is not in use

Warning

• 

Set the function switch to the appropriate position before measuring

• 

When measuring volts do not switch to current/resistance modes

• 

When changing ranges using the selector switch always disconnect 
the test leads from the circuit under test

• 

Do not exceed the maximum rated input limits

Caution

• 

Improper use of this meter can cause damage, shock, injury or death

• 

Read and understand this user manual before operating the meter

• 

Always remove the test leads before replacing the battery

• 

Inspect the condition of the test leads and the meter itself for any 
damage before operating

• 

Repair or replace any damage before use

• 

Individual protective equipment must be used around voltages above  
60V DC, 42.4V peak or 30V AC RMS

• 

Remove the battery if the meter is to be stored for long periods

• 

Always discharge capacitors and remove power from the device 
under test before performing diode, resistance, or continuity tests

• 

Voltage checks on electrical outlets can be difficult and misleading 
because of the uncertainty of connection to the recessed electrical 
contacts

• 

If the equipment is used in a manner not specified by the manufac-
turer, the protection provided by the equipment may be impaired

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание R5030

Страница 1: ...r with Temperature Instruction Manual Black Pantone 534 Blue 100 80 30 5 Pantone 485 Red 10 100 100 5 Pantone 123 Yellow 0 27 100 reedinstruments www com www GlobalTestSupply com Find Quality Products...

Страница 2: ...ty 3 Features 4 Specifications 4 5 Instrument Description 6 Operating Instructions 7 10 AC DC Current Measurements 7 AC DC Voltage Measurements 7 Resistance Measurements 7 Continuity Test 8 Diode Test...

Страница 3: ...per use of this meter can cause damage shock injury or death Read and understand this user manual before operating the meter Always remove the test leads before replacing the battery Inspect the condi...

Страница 4: ...d over range indications For indoor use in accordance with Overvoltage Category II Pollution Degree 2 Specifications Clamp Size Opening 1 2 30mm approx Diode Test Test current of 0 3mA typical Open ci...

Страница 5: ...ltage 500 00 mVDC 0 1 5 digits 5 0000 VDC 0 1 4 digits 50 000 VDC 500 00 VDC 1000 0 VDC 0 5 4 digits AC Voltage True RMS 50 Hz to 1000 Hz 500 00 mVAC 1 0 40 digits 5 0000 VAC 1 0 30 digits 50 000 VAC...

Страница 6: ...gger 5 MODE select button 6 LCD display 7 COM input jack 8 Data Hold and Backlight button 9 Rotary Function switch 10 Relative button 11 Hz Hold button 12 V CAP TEMP Hz jack Display Description 1 Auto...

Страница 7: ...ge Measurements 1 Insert the black test lead into the negative COM terminal and the red test lead into the positive V terminal 2 Set the function switch to the V position and select either AC or DC wi...

Страница 8: ...y 3 Touch the test probe tips to the diode or semiconductor junction under test Note the meter reading 4 The diode or junction can be evaluated as follows If one reading displays a value typically 0 4...

Страница 9: ...button again to indicate on the display 6 Read the of duty cycle on the display Temperature Measurements 1 To avoid electric shock disconnect both test probes from any source of voltage before making...

Страница 10: ...ximity to the live conductor 3 The detector is designed with high sensitivity Static electricity or other sources of energy may randomly trip the sensor Data Hold and Backlight 1 While taking a measur...

Отзывы: