reedinstruments
www
com
5
Electrical Specifications
Function
Range
Resolution
Accuracy
Overload
Protection
DC/AC
Voltage
(DC only)
400mV
0.1mV
± (0.5% + 2d)
AC/DC 1000V
4V
0.001V
DC:
± (1% + 2d)
AC:
± (1.2% + 5d)
40V
0.01V
400V
0.1V
1000V
1V
DC/AC
Current
(Direct input)
400uA
0.1uA
± (1.2% + 5d)
AC/DC 500mA
4000uA
1uA
40mA
0.01mA
400mA
0.1mA
DC/AC
Current
(Clamp on)
400A
0.1A
± (2% + 5d)
AC/DC
2000A/1000V
2000A
1A
± (2% + 8d)
Ohms
400 ohm
0.1 ohm
± (1% + 5d)
AC/DC 400V
4K ohm
1 ohm
40K ohm
10 ohm
400K ohm
100 ohm
4M ohm
1K ohm
± (2% + 2d)
40M ohm
10K ohm
± (3.5% + 5d)
Capacitance
50nF
10pF
± (3% + 5d)
* See Notes On
Following Page
AC/DC 400V
500nF
100pF
5uF
0.001uF
50uF
0.01uF
Frequency
(>5V)
5Hz
0.001Hz
± (1% + 5d)
AC/DC 1000V
50Hz
0.01Hz
500Hz
0.1Hz
5KHz
1Hz
50KHz
0.01KHz
100KHz
0.1KHz
Duty Cycle
1% to 99%
0.10%
Diode
Short/non conductance, good/detect test
Continuity
Meter will beep if measuring resistance is less than 10 ohm