Страница 1: ...Radiation Detector Instruction Manual R8008 REED Instruments 1 877 849 2127 info reedinstruments com www reedinstruments com...

Страница 2: ...ccumulation Time 8 Pulse Counting 9 Data Storage 9 10 Bluetooth Recording Mode 10 Battery Life Indicator 10 Setup Menu 10 12 Set Date 10 Set Time 11 Setting Alarm Threshold 11 Enabling Disabling Pulse...

Страница 3: ...acing batteries may cause damage that will not be covered under the manufacturer s warranty Servicing should only be provided by an authorized service center Features Detects Alpha Beta Gamma and X ra...

Страница 4: ...gital Bargraph Indicator Yes Adjustable Alarms Yes Audible Visual Indicators Average Time Function 2 to 120 seconds Natural Environment Reading 0 to 0 2 Sv h Datalogging Capabilities Yes Real Time Clo...

Страница 5: ...on 9 ESC Button 10 Battery Up Arrow 11 Dose Button 12 Pulse Button Display Description 1 Boot Nuclear Radiation Measuring Icon 2 Date Time Icon 3 Setup Menu Indicators 4 Measuring Function Indicators...

Страница 6: ...horized distributor or customer service at info reedinstruments com or 1 877 849 2127 Operating Instructions The R8008 is intended to detect the radiation dose rate of and X rays radiated from an obje...

Страница 7: ...or deactivate the LCD backlight The backlight will automatically turn off after 1 minute Unit Conversion for Dose Rate When the meter is powered ON the default unit of measurement is set to Sv h Pres...

Страница 8: ...digit 5 When ready press the and arrows to adjust the flashing digit 6 Press the button to confirm your selection and proceed to the next digit 7 When the last digit has been selected and confirmed t...

Страница 9: ...the set time refer to Setting Dose Accumulation Time for details 5 Throughout the measurement process the icon will blink on the LCD display 6 The meter will beep when the set time is up and the cumu...

Страница 10: ...meter s battery status press the button 2 The meter will now indicate the remaining internal battery voltage 3 Press the ESC button to resume normal operation Setup Menu You can adjust the following...

Страница 11: ...e Alarm Threshold Setup screen 4 Make sure to start with the leftmost digit 5 To toggle between digits press the enter button to move to the next digit or press the ESC button to return to the previou...

Страница 12: ...setup screen 4 Make sure to start with the leftmost digit 5 To toggle between digits press the button to move to the next digit or press the ESC button to return to the previous digit 6 When ready pr...

Страница 13: ...rument Use on external parts only Product Warranty REED Instruments guarantees this instrument to be free of defects in material or workmanship for a period of one 1 year from date of shipment During...

Страница 14: ...ED distributor or REED Instruments Customer Service by phone at 1 877 849 2127 or by email at info reedinstruments com Please visit www REEDINSTRUMENTS com for the most up to date manuals datasheets p...

Страница 15: ...Test Measure with Confidence Check out our latest Products REED Instruments 1 877 849 2127 info reedinstruments com www reedinstruments com...

Страница 16: ...REED Instruments 1 877 849 2127 info reedinstruments com www reedinstruments com...