background image

15

Data Logging

Data Recording Modes

Manual Data Logging:

 Press the 

LOG

 button to manually log up to 

99 readings on a SD memory card (see 

Manual Data Logging Mod

e for 

full setup instructions).

Automatic Data Logging: 

Setup the meter parameters in order to 

automatically log data on a SD memory card. The number of data points 

is limited by the size of the memory card.

Note:

 it is recommended to use a class 4 SDHC memory card between 1Gb 

and 16Gb. insert the SD memory card in the slot at the bottom of the meter. 

The card must be inserted with the label side facing the rear of the meter.

Manual Data Logging Mode

In manual mode, the 

LOG

 button is pressed to manually log a reading on 

the inserted SD card at any time. In order to setup the meter for manual 

data logging, follow steps 1 through 7 below.
1.  Set the data logging sampling rate to "0" seconds (see 

Setting the 

Data Logging Sampling Rate

 section for details).

2.  Press the 

REC

 button and "REC" will appear on the LCD.

3.  Press the 

LOG

 button to enter manual data logging function as 

indicated by "DATALOGGER".

4.  The meter will also display P-X (X = memory position number 

between 1 and 99).

5.  Press the   and   buttons to select one of the 99 data memory 

positions in which to record.

6.  Press the 

LOG

 button to save a reading to memory. 'DATALOGGER' 

will flash each time a data point is stored.

Note:

 If a card is not inserted or the card is defective, the meter will flash 

"EMPTY". in this case, power the meter OFF and try again with another 
SD memory card or verify that the card is correctly inserted.
7.  To exit manual data logging mode, press and hold the 

REC

 button 

2 seconds to resume normal operation.

continued...

 

REED Instruments

1-877-849-2127 | [email protected] | www.reedinstruments.com

Содержание R3100SD

Страница 1: ...Data Logging Conductivity TDS Salt Meter Instruction Manual R3100SD REED Instruments 1 877 849 2127 info reedinstruments com www reedinstruments com...

Страница 2: ...9 10 Data Hold 10 Recording Maximum and Minimum Readings 10 Backlight 10 Setup Mode 11 14 Formatting the SD Card Sd F 11 12 Setting the Time and Date dAtE 12 Setting the Data Logging Sampling Rate SP...

Страница 3: ...ling 22 Product Support 22 Introduction Thank you for purchasing your REED R3100SD Data Logging Conductivity TDS Salt Meter Please read the following instructions carefully before using your instrumen...

Страница 4: ...logger with integrated SD memory card optional User selectable sampling rate Easy to read backlit LCD display Data hold and Min Max functions Tripod mount for long term monitoring Low battery indicato...

Страница 5: ...External Memory Yes expandable up to 16GB with SD card optional Auto Shut off Yes after 10 minutes off Kick Stand Yes Tripod Mountable Yes Low Battery Indicator Yes Power Supply 6 x AA batteries or A...

Страница 6: ...POWER Backlight Button 2 Up Button 3 Time Button 4 SD Card Slot 5 LCD Display 6 Hold ESC A Button 7 Rec Enter B Button 8 Down Function Button 9 Log Set Sampling Check Button 10 RS 232 Output Jack 11 R...

Страница 7: ...us Indicator 5 SD Card Status Indicator 6 Temperature Unit of Measure 7 PPM Multiplication Range Indicator 8 Conductivity Measurement Indicator 9 Parts per million Measurement Indicator 10 Maximum and...

Страница 8: ...surements SALt for salt measurements 2 Release the button to confirm selection Note At start up the meter s default settings are Display Unit Conductivity Temperature Unit C Temp Compensation Factor 2...

Страница 9: ...valid for the 200 S range and not when the zero value is 2 0 S TDS Measurement 1 Connect the conductivity probe into the input jack 2 Select tdS function see Selecting Measurement Modes for details 3...

Страница 10: ...mode as indicated by REC on the LCD The meter will now begin recording maximum and minimum readings 2 While in recording mode A Press the REC button once and the maximum value will appear on the displ...

Страница 11: ...perature unit of measure C or F PEr C Set Conductivity temperature compensation factor ESC Exit Setup mode 3 Once the appropriate parameter has been selected follow the instructions below Formatting t...

Страница 12: ...e ESC button to exit the Setup mode and resume normal operation The internal clock will keep accurate time when the meter is powered off When new batteries are installed the clock will have to be rese...

Страница 13: ...Press the ENTER button to confirm selection 3 Press the SET button to save and skip to next parameter Note At any time you can press the ESC button to exit the Setup mode and resume normal operation...

Страница 14: ...pears on the LCD 1 Press the and buttons to select the desired temperature compensation The default value is 2 per C 2 Press the ENTER button to confirm selection 3 Press the SET button to save and sk...

Страница 15: ...ng follow steps 1 through 7 below 1 Set the data logging sampling rate to 0 seconds see Setting the Data Logging Sampling Rate section for details 2 Press the REC button and REC will appear on the LCD...

Страница 16: ...ton and DATALOGGER will stop flashing To resume press the LOG button again 5 To end the current data logging session press and hold the REC button for 2 seconds Transferring Data from the SD Memory Ca...

Страница 17: ...internal air bubble drift out from under the sensing head 5 The LCD display will indicate the conductivity value 6 Press the A and B buttons simultaneously to enter calibration mode 7 The LCD display...

Страница 18: ...normal operation Data Stream Output Using Terminal application a data stream can be viewed from the RS 232 output connect RS 232 USB cable between the product and terminal PC and use the following set...

Страница 19: ...for 2 seconds 3 If resetting the meter does not resolve the issue please return the meter to the nearest authorized REED distributor or authorized Service Center for repair Battery Replacement When th...

Страница 20: ...ted here For a complete list of all accessories and replacement parts visit your product page on www reedinstruments com Frequently Asked Questions FAQ s I cannot turn off my meter do you know why Oft...

Страница 21: ...d accessories with biodegradable cleaner Do not spray the cleaner directly on the instrument Use on external parts only Product Warranty REED Instruments guarantees this instrument to be free of defec...

Страница 22: ...ED distributor or REED Instruments Customer Service by phone at 1 877 849 2127 or by email at info reedinstruments com Please visit www REEDINSTRUMENTS com for the most up to date manuals datasheets p...

Страница 23: ...Test Measure with Confidence Check out our latest Products REED Instruments 1 877 849 2127 info reedinstruments com www reedinstruments com...

Страница 24: ...REED Instruments 1 877 849 2127 info reedinstruments com www reedinstruments com...

Отзывы: