background image

 

19 

 

 

 

 

Please Note:- The fitting of Spare Parts must be supervised by a suitably qualified person.

  

 

Front Cover Revive     

  Cat No. 93672174  

Thermal Cut-Out       

  Cat No. 93672109

 

 

Front Cover Revive-Plus    Cat No. 93672175  

Pressure Switch Assembly    Cat No. 93672124

 

 

Heat Exchanger (7.2kW)     Cat No. 93672122  

Terminal Block Set              Cat No. 93672128

 

 

Heat Exchanger (8.5kW)     Cat No. 93672102  

End Cap c/w Metal Clip 

  Cat No. 93672178  

 

Heat Exchanger (9.5kW)     Cat No. 93672103  

Elbow c/w Metal Clip 

  Cat No. 93672179 

 

Heat Exchanger Vessel  

  Cat No. 93672183  

Metal Clip Set 

 

  Cat No. 93672180 

 

Solenoid Valve 

 

  Cat No. 93672176  

6-Mode Handset 

 

  Cat No. 93672159

 

 

Start / Stop Switch   

  Cat No. 93590713  

Chrome Shower Hose  

  Cat No. 93672119 

 

Flow Valve Top Assembly    Cat No. 93672105   

 

Ø25mm Hose Retainer 

  Cat No. 93672163 

 

Tank Clip 

 

 

  Cat No. 93672106  

Ø25mm Height Adjuster    Cat No. 93672161 

 

Pressure Relief Device 

  Cat No. 93672107  

Ø25mm Riser Rail Tube 

  Cat No. 93672158 

 

Heat Exchanger ‘O’-Rings    Cat No. 93672108  

Ø25mm Riser Rail Brackets   Cat No. 93672160

 

 

 

Detachable Lower Section    Cat No. 93672177  

Ø25mm Clear Soap-Dish    Cat No. 93672162 

 

Phased Shut-Down Relay    Cat No. 93597878  

Phased Shut-Down PCB 

  Cat No. 93550835 

 

 
 

Expressions Revive Showers 

Expressions Revive-Plus Showers 

COMMON SPARE PARTS 

CIRCUIT DIAGRAMS 

Содержание EXPRESSIONS REVIVE

Страница 1: ...IMPORTANT This booklet should be left with the user after installation and demonstration Installation and User Guide EXPRESSIONS REVIVE and EXPRESSIONS REVIVE PLUS SMARTFIT 2 ELECTRIC SHOWERS...

Страница 2: ...form to any local regulations in effect This appliance is intended to be permanently connected to the fixed electrical wiring of the mains supply with its own dedicated supply This appliance must NOT...

Страница 3: ...ting may give adequate hot water Your shower is designed to stabilise temperature changes caused by water pressure fluctuations These can result from toilets being flushed or taps being turned on and...

Страница 4: ...front cover a poor fit 3 Adjust the position to get the most convenient arrangement taking the following into account DO NOT MOUNT THE UNIT IN THE DIRECT HANDSET SPRAY The handset must not be able to...

Страница 5: ...BING WARNING ENSURE THAT THE MAINS WATER SUPPLY MEETS THE REQUIREMENTS BELOW BEFORE CONTINUING INSTALLATION The shower unit must be connected to the mains cold water supply This must have a minimum su...

Страница 6: ...6 Showing Right Side Entry Left Side Entry is available for all options by exchanging the fitted end cap fig 7 5 2 5a 2 5b 2 5c 2 5d 2...

Страница 7: ...7 7 5e 2 5f 2 6 2 Also refer to page 8 for further water inlet entry information...

Страница 8: ...the spring clip back into position fig 8b Ensure end cap is securely fitted to previous pipe entry Rear Entry positions If Right Entry swivel the fitted compression elbow to face a rear entry pipe con...

Страница 9: ...nces 2 A means for disconnection in all poles must be incorporated in the fixed wiring in accordance with the wiring rules We recommend a ceiling switch mounted in a convenient position 3 Cut back cab...

Страница 10: ...full turn mid position should be at approximately 1 o clock 11 If you have not yet done so assemble your Smart Fit Accessories fig 12 12 Set the power select knob to COLD position and check the tempe...

Страница 11: ...sure the round opening points downward 3 Put the shower holder hose retainer and soap dish into the sliding rail and ensure the larger opening of the shower holder point upward Be sure that the notch...

Страница 12: ...at you do not wholly enter the water spray during this period especially if the shower has just been used If the water is not at your desired showering temperature turn Knob B a small amount until the...

Страница 13: ...djusted The COLD setting of Knob A will supply water without any heating During normal operation if an overheated water temperature is sensed then the heating elements will be switched off The Power l...

Страница 14: ...ARS WITH OUR APPROVED PART IN ORDER TO MAINTAIN THE PERFORMANCE OF YOUR SHOWER YOU MUST CLEAN THE SHOWER HANDSET REGULARLY YOU MUST REGULARLY INSPECT THE HANDSET FOR WEAR AND DAMAGE AND REPLACE IF NEC...

Страница 15: ...d water temperature is achieved by adjusting the rate of water flow The diagram shows the principle involved in relating temperature rise to flow rate The higher the water rate the lower the temperatu...

Страница 16: ...ly Fully open service valve stop cock Check hose is not kinked restricting the water flow Clean handset Check and clean filter if necessary Water too COLD Decrease water flow by adjusting Knob B clock...

Страница 17: ...liser valve Check stabiliser is in place and remove any debris in valve Water discharge from pressure relief valve Check for cause of high pressure and remove it Blockage on outlet e g blocked shower...

Страница 18: ...e slot d Pressure Relief Device m Wall Fixing Slot e On Off Solenoid Valve n Relay Expressions Revive Plus only f Pressure Switch o Timer PCB Expressions Revive Plus only g Terminal Block x 2 p Power...

Страница 19: ...tal Clip Set Cat No 93672180 Solenoid Valve Cat No 93672176 6 Mode Handset Cat No 93672159 Start Stop Switch Cat No 93590713 Chrome Shower Hose Cat No 93672119 Flow Valve Top Assembly Cat No 93672105...

Страница 20: ...up Limited or our approved agents g Service under guarantee has no effect on the expiry date The guarantee on any exchanged parts or product ends when the original guarantee period ends EXCLUSIONS Thi...

Отзывы: