background image

 

14 

 

 

 

It is recommended that the shower unit and accessories be cleaned using a                                                      

soft cloth and that the use of abrasive or solvent based cleaning fluid be avoided,                                                               
especially on any plated finishes.   

 

We recommend that before any cleaning, the isolating switch be turned off,                                                       
thus avoiding accidentally switching on the shower. 

 

All water contains particles of lime-scale, which build up in the shower handset                                                                  

and unit reducing the performance. 

 

It is therefore important to clean the shower handset by simply rubbing the                                                     
rubber nozzles, or soaking in a proprietary lime-scale remover and rinsing                                                     
thoroughly before use.  

 

NOTE:

   

After use it is normal for some water to drip from the shower handset for                                                           
a few moments.  This inhibits lime-scale build-up over prolonged use.  

 

WARNING:  
YOU MUST REGULARLY INSPECT THE SHOWER HOSE FOR WEAR AND 
DAMAGE AND REPLACE IF NECESSARY, OR EVERY 2 YEARS, WITH OUR 
APPROVED PART. 

 

IN ORDER TO MAINTAIN THE PERFORMANCE OF YOUR SHOWER, 
YOU MUST CLEAN THE SHOWER HANDSET REGULARLY. 

 

YOU MUST REGULARLY INSPECT THE HANDSET FOR WEAR AND 
DAMAGE AND REPLACE IF NECESSARY, WITH OUR APPROVED PART. 

 
CLEANING THE FILTER 

 

It is recommended that the filter is periodically cleaned in order to maintain the performance of the 
shower.  It is essential that this operation is carried out by a competent person. 

 

WARNING!  
SWITCH OFF WATER SUPPLY AT THE MAINS BEFORE REMOVING FILTER. 

 

The inlet filter is situated inside the water inlet fitting 

(fig.19)

 

To gain access there is 

no need

 to remove                                                                                                        

the front cover and backplate lower section.                                                                                                                                        

 

Unscrew the filter body on the water inlet fitting 

(fig.18)

 

Remove the filter body and flush with clean water                                                                                                       
and then replace. 

 

When cleaning the filter, 

DO NOT

 use a sharp object,                                                                                                                                

as it will cause damage.  
It is preferable to use an old toothbrush or similar 

 

The metal filter mesh is best to be cleaned when it is                                                                                                   
on the body as shown. 

 

Take care to re-position the filter correctly. 

 

18

 

HOW TO MAINTAIN YOUR SHOWER 

Содержание EXPRESSIONS REVIVE

Страница 1: ...IMPORTANT This booklet should be left with the user after installation and demonstration Installation and User Guide EXPRESSIONS REVIVE and EXPRESSIONS REVIVE PLUS SMARTFIT 2 ELECTRIC SHOWERS...

Страница 2: ...form to any local regulations in effect This appliance is intended to be permanently connected to the fixed electrical wiring of the mains supply with its own dedicated supply This appliance must NOT...

Страница 3: ...ting may give adequate hot water Your shower is designed to stabilise temperature changes caused by water pressure fluctuations These can result from toilets being flushed or taps being turned on and...

Страница 4: ...front cover a poor fit 3 Adjust the position to get the most convenient arrangement taking the following into account DO NOT MOUNT THE UNIT IN THE DIRECT HANDSET SPRAY The handset must not be able to...

Страница 5: ...BING WARNING ENSURE THAT THE MAINS WATER SUPPLY MEETS THE REQUIREMENTS BELOW BEFORE CONTINUING INSTALLATION The shower unit must be connected to the mains cold water supply This must have a minimum su...

Страница 6: ...6 Showing Right Side Entry Left Side Entry is available for all options by exchanging the fitted end cap fig 7 5 2 5a 2 5b 2 5c 2 5d 2...

Страница 7: ...7 7 5e 2 5f 2 6 2 Also refer to page 8 for further water inlet entry information...

Страница 8: ...the spring clip back into position fig 8b Ensure end cap is securely fitted to previous pipe entry Rear Entry positions If Right Entry swivel the fitted compression elbow to face a rear entry pipe con...

Страница 9: ...nces 2 A means for disconnection in all poles must be incorporated in the fixed wiring in accordance with the wiring rules We recommend a ceiling switch mounted in a convenient position 3 Cut back cab...

Страница 10: ...full turn mid position should be at approximately 1 o clock 11 If you have not yet done so assemble your Smart Fit Accessories fig 12 12 Set the power select knob to COLD position and check the tempe...

Страница 11: ...sure the round opening points downward 3 Put the shower holder hose retainer and soap dish into the sliding rail and ensure the larger opening of the shower holder point upward Be sure that the notch...

Страница 12: ...at you do not wholly enter the water spray during this period especially if the shower has just been used If the water is not at your desired showering temperature turn Knob B a small amount until the...

Страница 13: ...djusted The COLD setting of Knob A will supply water without any heating During normal operation if an overheated water temperature is sensed then the heating elements will be switched off The Power l...

Страница 14: ...ARS WITH OUR APPROVED PART IN ORDER TO MAINTAIN THE PERFORMANCE OF YOUR SHOWER YOU MUST CLEAN THE SHOWER HANDSET REGULARLY YOU MUST REGULARLY INSPECT THE HANDSET FOR WEAR AND DAMAGE AND REPLACE IF NEC...

Страница 15: ...d water temperature is achieved by adjusting the rate of water flow The diagram shows the principle involved in relating temperature rise to flow rate The higher the water rate the lower the temperatu...

Страница 16: ...ly Fully open service valve stop cock Check hose is not kinked restricting the water flow Clean handset Check and clean filter if necessary Water too COLD Decrease water flow by adjusting Knob B clock...

Страница 17: ...liser valve Check stabiliser is in place and remove any debris in valve Water discharge from pressure relief valve Check for cause of high pressure and remove it Blockage on outlet e g blocked shower...

Страница 18: ...e slot d Pressure Relief Device m Wall Fixing Slot e On Off Solenoid Valve n Relay Expressions Revive Plus only f Pressure Switch o Timer PCB Expressions Revive Plus only g Terminal Block x 2 p Power...

Страница 19: ...tal Clip Set Cat No 93672180 Solenoid Valve Cat No 93672176 6 Mode Handset Cat No 93672159 Start Stop Switch Cat No 93590713 Chrome Shower Hose Cat No 93672119 Flow Valve Top Assembly Cat No 93672105...

Страница 20: ...up Limited or our approved agents g Service under guarantee has no effect on the expiry date The guarantee on any exchanged parts or product ends when the original guarantee period ends EXCLUSIONS Thi...

Отзывы: