PowerSmoke

 ADAPTOR

 

 INSTALLATION

Safety Warnings: 

• The maximum test pressure a PowerSmoke™ Adaptor may restrain can only be estimated 
• Slippage of a PowerSmoke™ Adaptor is influenced by many factors including debris / residue in the Intake / Exhaust system, 
coefficient of friction, internal pressure of the  PowerSmoke™ Adaptor, and the accuracy of inflation instruments 
• Generally, a PowerSmoke™ Adaptor properly inserted into an Intake / Exhaust system may begin slipping when test pressure exceeds 
50% of the internal inflation pressure. Inflation pressure and back pressure limitations are subject to temperature / humidity change
• PowerSmoke™ Adaptor should NEVER be inflated over 1.6 times its outside diameter
• Debris, protrusions and residue in the Intake / Exhaust system could weaken and / or rupture the bladder of the PowerSmoke™ 
Adaptor. Bladder failures due to misuse or abuse are not covered by warranty. Redline Detection shall not be responsible for any 
incidental or consequential damages 
• PowerSmoke™ Adaptor must be mechanically anchored with the provided chain / cable to a secure location before use.
• PowerSmoke™ Adaptor slippage under test pressures may cause property damage or injury
• NEVER use inflation pressure with PowerSmoke™ Adaptor or a test pressure that is greater than the capacity of the weakest 
component in the system under test 
• NEVER use PowerSmoke™ Adaptor when its failure could cause injury or catastrophic damage 
• Before use: Refer to PowerSmoke™ Adaptor Installation and Inflation procedures, back pressure limitations and tether restraint 
installation instructions
1. Install PowerSmoke™ Adaptor fully into intake system ductwork or exhaust tubing. Make sure there are no obstructions or sharp 
edges that might puncture bladder when inflated. PowerSmoke™ Adaptor must insert completely inside ducting / tubing  
2. Install safety chain / cable to a secure location
3. Inflate PowerSmoke™ Adaptor to 30 PSI (2 BAR) maximum. If over inflated, pop off safety valve may release. If release occurs, 
reinflate to 30 PSI (2 BAR)
4. Firmly tug on safety chain to insure PowerSmoke™ Adaptor is firmly installed and properly secure
5. Attach vapor hose for testing 

                                                                                           

Removal of PowerSmoke™ Adaptor: 

1. Remove vapor hose (or block-off coupler) at quick coupler to deflate tested system 
2. ONLY AFTER system under test is fully depressurized, release internal pressure of PowerSmoke™ 
    slowly by depressing Schrader valve
3. Detach safety chain / cable
4. Remove PowerSmoke™ Adaptor from ductwork, making sure not to rub across sharp edges 

                          

Read all safety instructions in the Safety Information section of the Engine Service Manual or 

Engine Diagnostic Manual. Failure to comply may result in personal injury and / or death.

SAFETY TIPS

 

• All diagnostic work should be performed with the engine off

 

• Do NOT use in EVAP system 

 

• Ensure that the vehicle is secure and stable

 

• Exercise caution when connecting and disconnecting compressed shop air supply

 

• Do NOT leave a vehicle unattended while equipment is operating

 

• Always wear proper safety protection

 

• This safety guide is not intended to take the place of common sense and good judgment

Proper Installation

Improper Installation

Содержание GM POWER SMOKE RLD950103GM

Страница 1: ...OPERATION MANUAL P N RLD950103GM DIAGNOSTIC LEAK DETECTOR GM ...

Страница 2: ...allation 6 Testing for Leaks 7 8 Trouble Shooting 8 Warranty 9 Replacement Parts 9 Technical Support 1 866 55 SMOKE 1 714 451 1411 GM Technical Support 1 800 GM TOOLS Email Support info RedlineDetection com You will receive a call or email response within six 6 hours Shop Online www RedlineDetection com ...

Страница 3: ...ompressed Air Output Pressure 2 to 20 PSI 0 14 to 1 4 BAR Operating Temperature 0 F to 140 F 17 C to 60 C Operating Humidity No Restrictions Operating Altitude No Restrictions Smoke Output Hose 15 ft 5 m 12V Power Cable 15 ft 5 m Operating Modes Smoke Cycle Air Only Cycle Housing Material Steel Smoke Chamber Material Billet Aluminum Smoke Chamber Assembly Bolted Smoke Chamber Warranty Lifetime GM ...

Страница 4: ...cycle Push again to stop testing 6 Air Only Test Switch Begins ten minute air only cycle Blue light indicates air only cycle Push again to stop testing 7 Reset Switch Clears stored logic 8 Adjustable Pressure Regulator Adjust test pressure from 2 to 20 PSI 0 14 to 1 4 BAR 9 Test Pressure Gauge Indicates test pressure set by regulator 10 Fluid Fill Port Remove fluid fill plug to fill machine with O...

Страница 5: ... debris residue in the Intake Exhaust system coefficient of friction internal pressure of the PowerSmoke Adaptor and the accuracy of inflation instruments Generally a PowerSmoke Adaptor properly inserted into an Intake Exhaust system may begin slipping when test pressure exceeds 50 of the internal inflation pressure Inflation pressure and back pressure limitations are subject to temperature humidi...

Страница 6: ...sure cable is rated to match input voltage and plug configuration 9 GM Approved Smoke Producing Fluid 8 fl oz 237 ml RLD960039GM Smoke Producing Fluid will perform over 500 typical tests per bottle Important Contains NO Dye Contaminants 10 Hex Key RLD800009 To remove replace fluid fill port plug 11 Oxygen Sensor Port Adaptor RLD150059 Use to access exhaust system through oxygen sensor port 12 Temp...

Страница 7: ...onnect a properly rated power cord into the AC Power Port a GREEN LIGHT indicates power is ON DO NOT connect GM POWERSMOKE Diagnostic Leak Detector to a battery charger or jumper box NEVER connect GM POWERSMOKE Diagnostic Leak Detector to a vehicle with engine running 3 CONNECT TO PRESSURIZED AIR SUPPLY a Connect compressed air supply to Air Inlet Replace quick coupler fitting if necessary 1 4 in ...

Страница 8: ...tallation and Inflation procedures back pressure limitations and tether restraint installation instructions 1 Install PowerSmoke Adaptor fully into intake system ductwork or exhaust tubing Make sure there are no obstructions or sharp edges that might puncture bladder when inflated PowerSmoke Adaptor must insert completely inside ducting tubing 2 Install safety chain cable to a secure location 3 In...

Страница 9: ...ted from the air box to the tip of the exhaust completely in a single test To do so install PowerSmoke Adaptor see instructions into intake ducting after air cleaner box AND install PowerSmoke Adaptor see instructions into exhaust pipe Convert PowerSmoke Adaptor in exhaust system into a block off by installing block off coupler Inject smoke into the intake system through the PowerSmoke Adaptor Pre...

Страница 10: ... either with decay testing or using visible vapor First attach optional cooling system adaptor to pressurized coolant bottle or radiator at cap For decay testing simply pressurize coolant system with air only to manufacturers recommended test pressure typically 15 PSI 1 BAR Turn off flow control valve to lock out system and watch for decay Inspect visually for leaking fluid Alternatively to perfor...

Страница 11: ...d of the purchase price This warranty shall void if a product is improperly maintained altered abused or otherwise misused in any way THE AFORESAID WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES AND THERE ARE NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER MADE BY REDLINE EITHER EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PA...

Страница 12: ...Manufactured By Redline Detection LLC Technical Support 1 714 451 1411 Shop Online www RedlineDetection com with global components ...

Отзывы: