PROBLEM                                                SOLUTION

No Green Light 

 

 

            • Check for proper battery voltage

 

 

 

            • Align power supply switch with input (AC or DC)

 

 

 

            • Check polarity if 12V DC is selected

 

 

 

            • Check fuse if AC Power is selected

 

   

 

 

     

Red Light Flashing                        

 

            • Open circuit / internal component

 

 

 

            • Contact Redline Technical Support

 

 

 

 

  866-55-SMOKE or +1 714-451-1411 

 

 

 

 

  Email: [email protected]

No Air Flow 

 

 

            • Check connection to compressed air

 

 

 

            • Open the flow control valve

 

 

 

            • Check hoses are not kinked or pushed into machine

                                                                
Poor Smoke Density or Volume   

 

            • Insufficient Smoke Producing Fluid: Refill

 

 

 

            • Flow Control Valve is partially closed

                                                                 

            • Smoke Output Hose is kinked 

  

High Test Pressure Reading 

 

 

            • Smoke Output Hose is kinked    

Coolant System Leak Testing 

Cooling system leak testing can be performed two ways

Use GM Power Smoke™ to quickly and easily find cooling system leaks either with decay testing or using 

visible vapor.  First, attach (optional) cooling system adaptor to pressurized coolant bottle or radiator at 

cap.  For decay testing, simply pressurize coolant system with air-only to manufacturers recommended 

test pressure, typically 15 PSI (1 BAR).  Turn off flow control valve to lock out system and watch for 

decay. Inspect visually for leaking fluid.  Alternatively, to perform leak test using smoke vapor, first drain 

the cooling system of all fluid. Introduce pressurized vapor in to cooling system at no more than the 

manufacturers recommended test pressure and use inspection light to find leaks. Retest after repairs are 

performed to confirm proper repair and seal.  

         

    

 

IMPORTANT NOTE

 

Many leaks in systems are considered “normal” or “within tolerance.” For example,  

 

 

 

a weep hole in a muffler is acceptable.  DO NOT assume every wisp of smoke represents a 

 

failing component. Check with vehicle manufacturer before replacing suspected failed part. 

!     

TROUBLESHOOTING

TESTING FOR LEAKS CONTINUED

Содержание GM POWER SMOKE RLD950103GM

Страница 1: ...OPERATION MANUAL P N RLD950103GM DIAGNOSTIC LEAK DETECTOR GM ...

Страница 2: ...allation 6 Testing for Leaks 7 8 Trouble Shooting 8 Warranty 9 Replacement Parts 9 Technical Support 1 866 55 SMOKE 1 714 451 1411 GM Technical Support 1 800 GM TOOLS Email Support info RedlineDetection com You will receive a call or email response within six 6 hours Shop Online www RedlineDetection com ...

Страница 3: ...ompressed Air Output Pressure 2 to 20 PSI 0 14 to 1 4 BAR Operating Temperature 0 F to 140 F 17 C to 60 C Operating Humidity No Restrictions Operating Altitude No Restrictions Smoke Output Hose 15 ft 5 m 12V Power Cable 15 ft 5 m Operating Modes Smoke Cycle Air Only Cycle Housing Material Steel Smoke Chamber Material Billet Aluminum Smoke Chamber Assembly Bolted Smoke Chamber Warranty Lifetime GM ...

Страница 4: ...cycle Push again to stop testing 6 Air Only Test Switch Begins ten minute air only cycle Blue light indicates air only cycle Push again to stop testing 7 Reset Switch Clears stored logic 8 Adjustable Pressure Regulator Adjust test pressure from 2 to 20 PSI 0 14 to 1 4 BAR 9 Test Pressure Gauge Indicates test pressure set by regulator 10 Fluid Fill Port Remove fluid fill plug to fill machine with O...

Страница 5: ... debris residue in the Intake Exhaust system coefficient of friction internal pressure of the PowerSmoke Adaptor and the accuracy of inflation instruments Generally a PowerSmoke Adaptor properly inserted into an Intake Exhaust system may begin slipping when test pressure exceeds 50 of the internal inflation pressure Inflation pressure and back pressure limitations are subject to temperature humidi...

Страница 6: ...sure cable is rated to match input voltage and plug configuration 9 GM Approved Smoke Producing Fluid 8 fl oz 237 ml RLD960039GM Smoke Producing Fluid will perform over 500 typical tests per bottle Important Contains NO Dye Contaminants 10 Hex Key RLD800009 To remove replace fluid fill port plug 11 Oxygen Sensor Port Adaptor RLD150059 Use to access exhaust system through oxygen sensor port 12 Temp...

Страница 7: ...onnect a properly rated power cord into the AC Power Port a GREEN LIGHT indicates power is ON DO NOT connect GM POWERSMOKE Diagnostic Leak Detector to a battery charger or jumper box NEVER connect GM POWERSMOKE Diagnostic Leak Detector to a vehicle with engine running 3 CONNECT TO PRESSURIZED AIR SUPPLY a Connect compressed air supply to Air Inlet Replace quick coupler fitting if necessary 1 4 in ...

Страница 8: ...tallation and Inflation procedures back pressure limitations and tether restraint installation instructions 1 Install PowerSmoke Adaptor fully into intake system ductwork or exhaust tubing Make sure there are no obstructions or sharp edges that might puncture bladder when inflated PowerSmoke Adaptor must insert completely inside ducting tubing 2 Install safety chain cable to a secure location 3 In...

Страница 9: ...ted from the air box to the tip of the exhaust completely in a single test To do so install PowerSmoke Adaptor see instructions into intake ducting after air cleaner box AND install PowerSmoke Adaptor see instructions into exhaust pipe Convert PowerSmoke Adaptor in exhaust system into a block off by installing block off coupler Inject smoke into the intake system through the PowerSmoke Adaptor Pre...

Страница 10: ... either with decay testing or using visible vapor First attach optional cooling system adaptor to pressurized coolant bottle or radiator at cap For decay testing simply pressurize coolant system with air only to manufacturers recommended test pressure typically 15 PSI 1 BAR Turn off flow control valve to lock out system and watch for decay Inspect visually for leaking fluid Alternatively to perfor...

Страница 11: ...d of the purchase price This warranty shall void if a product is improperly maintained altered abused or otherwise misused in any way THE AFORESAID WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES AND THERE ARE NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER MADE BY REDLINE EITHER EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PA...

Страница 12: ...Manufactured By Redline Detection LLC Technical Support 1 714 451 1411 Shop Online www RedlineDetection com with global components ...

Отзывы: