75

SET UP

  

  

1. FILL  / ADD APPROVED VAPOR PRODUCING FLUID

a. Remove vapor producing fluid fill plug with hex key
b. Pour GM-Approved Vapor Producing Fluid into vapor producing fluid fill port

Note: Use only GM-Approved Vapor Producing Fluid part number : RLD

960036

c. Fill vapor fluid fill port until fluid level is near top of port

2 fl. oz. (60 ml) maximum to refill when empty

d. Replace vapor producing fluid fill plug

Never use dye / UV dye in GM intake or exhaust systems because it 

may coat or harm critical sensors

2. CONNECT TO ELECTRICAL POWER SOURCE

•  Use the power selector switch on rear of machine to select input power, 

AC or DC

•  If 12 Volt DC is preferred, connect the battery cables to a fully charged  

12 Volt battery. RED to positive, BLACK to chassis ground

•  If AC power is preferred, connect a properly rated power cord into the  

AC Power Port

a.        GREEN LIGHT indicates power is ON

DO NOT connect GM POWERSMOKE

  Diagnostic  

Leak Detector to a battery charger or jumper box

NEVER connect GM POWERSMOKE

  Diagnostic  

Leak Detector to a vehicle with engine running 

3. CONNECT TO PRESSURIZED AIR SUPPLY

a. Connect compressed air supply to Air Inlet
   *Replace quick coupler fitting if necessary. 1/4 in. NPT male

4. ADJUST GM POWERSMOKE

 DIAGNOSTIC LEAK DETECTOR FOR TESTING

a. Close flow control valve
b. Pull pressure regulator knob to unlock
c. Push Vapor or Air Only Test to begin 10 minute cycle. Push again to stop

 

 RED LIGHT indicates Vapor Test

  BLUE LIGHT indicates Air Only Test

d. Turn pressure regulator knob to desired test pressure. To adjust,  

     turn clockwise to increase, counter clockwise to decrease.
e. Push pressure regulator knob to lock.

!

!

!

!

5. OPEN FLOW CONTROL VALVE TO RELEASE VAPOR / PRESSURE
6. USE INSPECTION LIGHT TO LOCATE LEAKS
7. PERFORM REPAIR
8. REPEAT TEST TO CONFIRM REPAIRS

Содержание GM POWER SMOKE RLD950103GM

Страница 1: ...OPERATION MANUAL P N RLD950103GM DIAGNOSTIC LEAK DETECTOR GM ...

Страница 2: ...allation 6 Testing for Leaks 7 8 Trouble Shooting 8 Warranty 9 Replacement Parts 9 Technical Support 1 866 55 SMOKE 1 714 451 1411 GM Technical Support 1 800 GM TOOLS Email Support info RedlineDetection com You will receive a call or email response within six 6 hours Shop Online www RedlineDetection com ...

Страница 3: ...ompressed Air Output Pressure 2 to 20 PSI 0 14 to 1 4 BAR Operating Temperature 0 F to 140 F 17 C to 60 C Operating Humidity No Restrictions Operating Altitude No Restrictions Smoke Output Hose 15 ft 5 m 12V Power Cable 15 ft 5 m Operating Modes Smoke Cycle Air Only Cycle Housing Material Steel Smoke Chamber Material Billet Aluminum Smoke Chamber Assembly Bolted Smoke Chamber Warranty Lifetime GM ...

Страница 4: ...cycle Push again to stop testing 6 Air Only Test Switch Begins ten minute air only cycle Blue light indicates air only cycle Push again to stop testing 7 Reset Switch Clears stored logic 8 Adjustable Pressure Regulator Adjust test pressure from 2 to 20 PSI 0 14 to 1 4 BAR 9 Test Pressure Gauge Indicates test pressure set by regulator 10 Fluid Fill Port Remove fluid fill plug to fill machine with O...

Страница 5: ... debris residue in the Intake Exhaust system coefficient of friction internal pressure of the PowerSmoke Adaptor and the accuracy of inflation instruments Generally a PowerSmoke Adaptor properly inserted into an Intake Exhaust system may begin slipping when test pressure exceeds 50 of the internal inflation pressure Inflation pressure and back pressure limitations are subject to temperature humidi...

Страница 6: ...sure cable is rated to match input voltage and plug configuration 9 GM Approved Smoke Producing Fluid 8 fl oz 237 ml RLD960039GM Smoke Producing Fluid will perform over 500 typical tests per bottle Important Contains NO Dye Contaminants 10 Hex Key RLD800009 To remove replace fluid fill port plug 11 Oxygen Sensor Port Adaptor RLD150059 Use to access exhaust system through oxygen sensor port 12 Temp...

Страница 7: ...onnect a properly rated power cord into the AC Power Port a GREEN LIGHT indicates power is ON DO NOT connect GM POWERSMOKE Diagnostic Leak Detector to a battery charger or jumper box NEVER connect GM POWERSMOKE Diagnostic Leak Detector to a vehicle with engine running 3 CONNECT TO PRESSURIZED AIR SUPPLY a Connect compressed air supply to Air Inlet Replace quick coupler fitting if necessary 1 4 in ...

Страница 8: ...tallation and Inflation procedures back pressure limitations and tether restraint installation instructions 1 Install PowerSmoke Adaptor fully into intake system ductwork or exhaust tubing Make sure there are no obstructions or sharp edges that might puncture bladder when inflated PowerSmoke Adaptor must insert completely inside ducting tubing 2 Install safety chain cable to a secure location 3 In...

Страница 9: ...ted from the air box to the tip of the exhaust completely in a single test To do so install PowerSmoke Adaptor see instructions into intake ducting after air cleaner box AND install PowerSmoke Adaptor see instructions into exhaust pipe Convert PowerSmoke Adaptor in exhaust system into a block off by installing block off coupler Inject smoke into the intake system through the PowerSmoke Adaptor Pre...

Страница 10: ... either with decay testing or using visible vapor First attach optional cooling system adaptor to pressurized coolant bottle or radiator at cap For decay testing simply pressurize coolant system with air only to manufacturers recommended test pressure typically 15 PSI 1 BAR Turn off flow control valve to lock out system and watch for decay Inspect visually for leaking fluid Alternatively to perfor...

Страница 11: ...d of the purchase price This warranty shall void if a product is improperly maintained altered abused or otherwise misused in any way THE AFORESAID WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES AND THERE ARE NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER MADE BY REDLINE EITHER EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PA...

Страница 12: ...Manufactured By Redline Detection LLC Technical Support 1 714 451 1411 Shop Online www RedlineDetection com with global components ...

Отзывы: