Red
CONNEX
TM
AN-80i
User
Manual
70-00072-01-04b
Proprietary Redline Communications © 2007
October 31, 2007
Page 29 of 94
Auto scan
:
Check this box to enable the PTP Slave automatically scan available
channels to locate and register with an AN-80i PTP Master. When the Auto Scan field is
checked, click on the blue text
[
Frequency Ranges
]
adjacent to the check box to display
the Frequency Management screen. Up to 32 frequency ranges may be specified.
Frequency ranges may be entered on the PTP Master and the PTP Slave. Settings entered
on the PTP Master will be downloaded and used by the PTP Slave.
Figure 11
:
Web - Wireless Configuration Screen
Add Frequency Range
Begin
: Enter the lower limit of the frequency scan interval (MHz). The scan interval must
be a subset of the region frequency range.
End
:
Enter the upper limit of the frequency scan interval (MHz). The scan interval must
be a subset of the region frequency range.
Add
: Click to check the range settings and add these to the Local Frequency Range list
(if valid). To save changes to non-volatile memory, return to the Configuration Screen
and click the
Save
button at the bottom of the screen.
Delete Frequency Range
Index
:
Select the index value for the scan interval delete from the Local Ranges table.
Delete
: Click the Delete button to permanently remove the selected scan interval.
Local Frequency Ranges:
These are the (optional) scan intervals for this PTP Slave. The last settings saved in non-