Red
CONNEX
TM
AN-80i
User
Manual
70-00072-01-04b
Proprietary Redline Communications © 2007
October 31, 2007
Page 26 of 94
IP Address
:
Enter the IP address for this AN-80i. The IP address is routable through the
Ethernet port and over the wireless interface.
IP Subnet
Mask
: Enter the IP subnet mask.
Default Gateway Address
:
Enter the IP address of the default gateway or router on the
Ethernet segment connected to the AN-80i Ethernet port.
Flow Control Enable
: Check this box to enable flow control functions (802.3x) on
the AN-80i Ethernet port. Enabling this feature allows the AN-80i to request Ethernet
devices to pause transmissions during busy periods.
Prioritized Low Latency Mode Enable
: Check this box to enable priority handling
of 802.1p tagged traffic. When enabled, this ensures prioritized traffic is transmitted with
the lowest achievable latency, even under conditions of high IP data traffic loading.
Table 3
:
Configuration - 802.1p Priority Settings
Priority Setting
Highest
6, 7
4,
5
0, 3, no tag
Lowest
1, 2
SNTP Enable
: Check this box to enable the SNTP protocol support. This feature
allows AN-80i systems to time-stamp log messages using a network time server. When
enabled, you must enter the network address of the SNTP server in the SNTP Server IP
Address field.
SNTP Server IP Address
: Enter the network address of the SNTP server. Valid only
when the SNTP Enable field is checked.
Polling Interval
: Enter the SNTP polling interval (hours).
Time Zone (GMT)
: Enter the hours offset from GMT for this time zone. Valid only
when the SNTP Enable field is checked.
Syslog Enable
: Check this box to enable the Syslog protocol support. This feature
allows AN-80i log messages to be saved in a central repository. When enabled, you must
enter the network address of the Syslog server in the Syslog Server IP Address field.
Syslog Server IP Address
: Enter the network address of the Syslog server. Valid only
when the Syslog Enable field is checked.
Ethernet Mode
:
Select the operating mode of the Ethernet port.
Auto
- Auto-negotiate the speed connection speed.
10
- Operate at 10Base-T only.
100
- Operate at 100Base-T only.
HD
- Operate at half-duplex only.
FD
- Operate in full duplex only.
Important
: The auto-negotiate feature does not detect the speed and duplex of
manually set Ethernet equipment. The auto-negotiate feature works correctly only
when both communicating Ethernet devices are configured for auto-negotiate. Duplex
mismatches may result in an unexpected loss of communications.