MegaPlus ES 1020
User’s Manual
Redlake MASD, Inc.
Page
15
91000134-001 Rev. A
Camera Mode
05
00
Camera mode status
Register 1
Read
Bit 15 1 = v bin x 4 enabled
Bit 14 1 = h bin x 4 enabled
Bit 13 1 = v bin x 2 enabled
Bit 12 1 = h bin x 2 enabled
Bit 11 1 = Positive trigger polarity
Bit 10 1 = Test Pattern Enabled
Bit 9
1 = Partial Scan Enabled
Bit 8
1 = ten bit mode enabled
Bit 7
1 = 8 x Gain
Bit 6
1 = 4 x Gain
Bit 5
1 = 2 x Gain
Bit 4
1 = 1 x Gain
Bit 3
1 = Trigger programmed exposure enabled
Bit 2
1 = Bit flip enabled
Bit 1
1 = Tap flip Enabled
Bit 0
1 = Single Tap Enabled
05
01
Camera mode status
Register 2
Read
Bit 15 not used
Bit 14 not used
Bit 13 not used
Bit 12 not used
Bit 11 not used
Bit 10 not used
Bit 9
not used
Bit 8
not used
Bit 7
not used
Bit 6
not used
Bit 5
not used
Bit 4
not used
Bit 3
not used
Bit 2
1 = Trigger double exposure enabled
Bit 1
1 = IBIT complete
Bit 0
1 = Trigger manual exposure enabled
Camera BIT status
06
00
Camera BIT Status
Register 1
Read
Bit 15 not used
Bit 14 not used
Bit 13 not used
Bit 12 not used
Bit 11 not used
Bit 10 not used
Bit 9
1 = CBIT fail
Bit 8
1 = IBIT fail
Bit 7
1 = Timing generator failed to configure
Bit 6
1 = Watchdog timer timeout
Bit 5
1 = Camera loaded from EEPROM
(0 = ROM)
Bit 4
1 = EEPROM failed read/write test
Bit 3
1 = Temp sensor failed read/write test
Bit 2
1 = B A to D failed read/write test
Bit 1
1 = A A to D failed read/write test
Bit 0
1 = Timing Generator failed read/write test
Содержание MegaPlus ES 1020