MegaPlus ES 1020
User’s Manual
Redlake MASD, Inc.
Page
24
91000134-001 Rev. A
•
VBIN 4/2: Vertical bin x 2 or x 4
Set to 1 to enable VBIN x 4
Set to 0 to enable VBIN x 2
•
VBIN ENABLE
Set to 0 to enable normal operation
Set to 1 to enable vertical binning
•
HBIN 4/2: Horizontal bin x 2 or x 4
Set to 1 to enable HBIN x 4
Set to 0 to enable HBIN x 2
•
HBIN ENBLE
Set to 0 to enable normal operation
Set to 1 to enable horizontal binning
Exposure and Control Register 2
15
14
13
12
11
10
9
8
CR2_3 CROSS
HAIR
ENABLE
LONG_VBI
N
LVDS
CLOCK x 2
EXP BIT 11
EXP BIT 10
EXP BIT 9
EXP BIT 8
7
6
5
4
3
2
1
0
EXP BIT 7
EXP BIT 6
EXP BIT 5
EXP BIT 4
EXP BIT 3
EXP BIT 2
EXP BIT 1
EXP BIT 0
•
EXP BIT 0 - 11
Manual
Exposure
•
LVDS CLOCK x 2 (note: set to 0 for normal operation, set to 1 for 2x LVDS clock)
Set to 0 to
Set to 1 to
•
LONG V BIN
Set to 0 to disable V bin x 8 and 16
Set to 1 to enable V bin x 8 and 16 (Choose via VBIN x 4/2)
•
CROSS HAIR ENABLE (note: use single tap mode for cross hair alignment)
Set to 0 to disable cross hair overlay
Set to 1 to enable cross hair overlay
•
CR2_3
Содержание MegaPlus ES 1020