Motion
Scope
â
PCI High Speed Video System
The Dialog box shown in Figure 3-14 gives details
of the record settings such as the record rate,
shutter setting, number of frames stored, length of
the sequence and the resolution of the video
frames in pixels.
Figure 3-14 The Camera Properties.
3.10 Using the Reticle to Measure Motion
The Reticle is a playback feature that puts reference markers on a recorded video image shown in
a camera or computer file window. This enables you to measure a location on an image, or
measure the motion of a point of interest from frame to frame. When you enable the Reticle
feature, the Reticle button shows the position of the pointer from the top left corner of the window.
When you click on a position, the Reticle horizontal and vertical lines move to that point. When
you right click on the picture, the system puts a colored marker on the point of point of interest.
3.10.1 Setting up the Reticle Parameters
Click on the Setup button and see the
Property dialog box. Click on Reticle for the
reticle details. See Figure 3-15. This shows
the following:
·
The width and color of the Reticle
lines. To increase the width, increase
the line width from 1 to 5. To change
the color of the Reticle line, click on
the
…
(Color) button, and select
another color from the range
displayed. Click Apply to view the
color, and OK to color the lines.
Figure 3-15 The Reticle Lines Settings.
·
The color of the Reticle Data Set
Points, Point In and Point Out
Of. The Data Point In is the
marker in the current frame.
Data Point Out Of is a marker
not in the current frame. To set
or change the Data Point color,
click on the
…
button, and select
a color from the range displayed.
Click Apply to view the color, and
OK to color the marker, see
Figure 3-16.
You can proceed with the default reticle
settings, or change the settings as
described. When you have activated the
Reticle feature as described in Section
3.10, you are ready to enter set points to
mark points of interest. If you want to
measure distances, you must follow the
Calibration procedure below.
Figure 3-16 Setting the Colors of the Data Set Points.