3.0 CONNECTIONS
Figure 3.1 shows the layout of the S0080.
Fig 3.1
3.1 24V DC Connectors
The unit is powered by 24V DC. Connection can be made via a 2.1mm DC jack or screw terminals. These two inputs are
connected in parallel inside the unit, so either could be used as an input, while the other could be used as a 24V DC out-
put to power another device.
Fig 3.2
SPECIAL NOTE ABOUT “AUTO MODE” OPERATION
If the timer is not displaying the main clock screen, where the time is changing, the unit is
not running in “Auto Mode”. This means it will not be checking any of the programmed
events and hence will not activate any outputs automatically.
Essentially this means that as soon as the Menu button is pressed the unit is no longer in
“Auto Mode”.
Make sure to return to the main screen by exiting all menu’s when not making changes.
7 Day 24 Hour Timer
Menu
Up
Down
Enter
+10
ZONE MODE
Manual Mode
Auto Mode
Press Zone buttons to
change Zone Mode
S 0080
24VDC
Input
24VDC
Input
+
-
DIP Switches Under
Auto/Manual Mode
LED Indicators
Zone 1
Zone 2
Zone 3
Zone 4
Output Closing Contacts
Zone On/Off
Indicators
Top Screw Cover
Bottom Screw Cover
OUTPUT 4
OUTPUT 3
OUTPUT 2
OUTPUT 1
N/O
N/C
COM
N/O
N/C
COM
N/O
N/C
COM
N/O
N/C
COM
24V DC Input
(2.1mm Jack)
24V DC Input
(screw terminals)
Acces to DIP
Switches