![Redback A 4505C Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/redback/a-4505c/a-4505c_operating-manual_1428873014.webp)
www.redbackaudio.com.au
Redback® Proudly Made In Australia
14
Redback® A 4505C
Lockdown Timer with Network Access
3.0 NETWORK ACCESS
The Redback® A 4505C has been upgraded from previous versions to now include access via a network connection. The
unit is connected with the addition of the Redback® A 4498 Network Connection Pack. With the upgraded PC software
all the event timing and audio file selection can be adjusted remotely.
Note: Audio files cannot be transferred via this connection. All audio files must be loaded onto the supplied Micro SD card
via the PC software. These files are stored in a Library on the SD card and can then be selected remotely.
Figure 3.1 below demonstrates how to connect the timer to a network via the Redback® A 4498 Connection Pack. The
pack includes a serial to ethernet converter, a proprietry adaptor board, a DC power lead and a short CAT6 lead for con-
nection between the A 4505C and the Adaptor board. The Serial to Ethernet Converter requires some configuration which
is outlined in the A 4498 instruction manual.
Once the Serial To Ethernet Converter setup is complete and all required connections made, the unit should now be acces-
sible via the PC software. Refer to the supplied Software Programming Guide for more information.
Note: An IT administrator or someone experienced with network protocols wil be required to setup the net-
work access.
Fig 3.1
Connecting the timer to a network via the Redback® A 4498 Connection Pack
Mic
Volume
To Paging
Console
To Wall Plate
Adapter
CR2032
Backup Battery Holder
(Use 3V CR2032 Battery Only)
Manufactured in Australia
By Altronic Distributors Pty. Ltd.
N/C
N/O
L
R
Audio
Out
Prebell
Level
V/Over
Level
DIP Switches
Common
24V Out
IMPORTANT NOTE
Ensure power is switched off when
adjusting DIP switches. New
settings will be effective when
power is switched back on.
N/C
N/O
Fire
24V Out
N/C
N/O
Lockdown
24V Out
N/C
N/O
Bell
24V Out
+
-
24V
DC In
+_
24V
DC In
Music
Level
Bell
Level
lock/Fire
Level
1 2 3 4 5 6 7 8
Battery
Backup
Cancel
Trigger
Fire
Trigger
Lockdn
Trigger
Bell
Trigger
ON
OFF
www.redbackaudio.com.au
1 2
3
4 5
6
7 8
Outputs limited to 120mA maximum current draw
Network
Serial Device Server
(Altronics D 4231)
Ether
net
RS485/422
DC 9-54V
Connect to the red RJ45 port.
Connect to Ethernet
network
Proprietry adaptor board
DC Power Lead
(Supplied)