Redback® A 4505C

 Lockdown Timer with Network Access

13 

Audio Out RCA Connectors 

 

Connect these outputs to the input of the background music amplifier.

14  

Bell Contact

 

 

These contacts are for remote triggering of the Bell tone. These could be triggered by a remote switch or other  

 

closing contact.

15  

Lockdown Contact

 

 

These contacts are for remote triggering of the Lockdown tone. These could be triggered by a remote switch or  

 

other closing contact.

16 

Fire Contact

 

 

These contacts are for remote triggering of the Fire tone. These could be triggered by a remote switch or 

 

other closing contact.

17  

Cancel Contact

 

 

These contacts are for remote triggering of the cancel function. These could be triggered by a remote switch or 

 

other closing contact.

18 

Mic Volume

 

Adjust this trimpot to adjust the Paging Microphone volume (Microphone currently not available).

19 

RJ45 interface

 

This RJ45 port is for connection of a microphone paging console (currently not available).

20 

RJ45 interface

 

This RJ45 port is for connection to the A 4599 or A 4599V wall plates.

21 

Dip Switches

 

These are used to select various options. Refer to DIP Switch Settings section.

22  

24V DC Input (Backup)

 

 

Connects to a 24V DC backup supply with at least 1 amp current capacity. (Please observe the polarity)

23 

24V DC input 

 

Connects to a 24V DC Plugpack with 2.1mm Jack.

Содержание A 4505C

Страница 1: ...E Please read these instructions carefully from front to back prior to installation They include important setup instructions Failure to follow these instructions may prevent the unit from working as...

Страница 2: ...d users reliable products of high build quality with local product support We believe there is significant added value for customers when purchasing an Australian made Redback amplifier or PA product...

Страница 3: ...vents Using The Supplied PC Software 10 2 5 Programming The Timing Events Using The Front Button 10 2 6 Deleting A Programmed Time 11 2 7 Reset All Programmed Times 11 2 8 EV Chanegover 12 2 9 Play Pr...

Страница 4: ...ockdown Fire and Bell tones and the cancel function are triggered by the front switches or by the rear terminal con tacts for remote activation Switched 24V DC Out connections are provided for Bell Lo...

Страница 5: ...of the Music Folders 5 99 is active 6 Menu and Navigation Switches These switches are used to navigate the menu functions of the unit 7 Isolate Switch This switch is used to isolate the timing functi...

Страница 6: ...3 0 for details 6 Backup Battery Switch Use this switch to activate the backup battery Note The backup battery only backs up the current time 7 Backup Battery Replace this battery with a 3V CR2032 onl...

Страница 7: ...be triggered by a remote switch or other closing contact 17 Cancel Contact These contacts are for remote triggering of the cancel function These could be triggered by a remote switch or other closing...

Страница 8: ...icated by the illumination of the relevant front panel indicator Note 2 To cancel a tone either use the remote cancel contacts or the front cancel button Note the cancel button will need to be depress...

Страница 9: ...5 EV CHANGEOVER 00 00 00 Mon NO TIME__00 00 00 Menu Main Screen Press the UP and DOWN buttons to scroll up and down Enter Press the ENTER button to make your selection Menu Press the MENU button to ex...

Страница 10: ...is option allows the user to enter the Station Event information which includes the event Turn on time Period and Output After selecting this option the screen as shown in Fig 2 5a should appear Fig 2...

Страница 11: ...sets each day ON or OFF Use the up and down buttons to set the day to Y for ON and N for OFF Once the days of the week are set press the enter button to confirm and be returned to the main menu Repea...

Страница 12: ...als up to 600 seconds NOTE If the changeover time is set to 0 the changeover will be de activated and therefore the unit will not switch over from the Alert cycle to the Evac cycle automatically 2 9 P...

Страница 13: ...olume setting on the individual volume control attenuator Lockdown Fire 24V Out These contacts are for switched 24V outputs whenever the Lockdown or Fire tones are activated These may be used to run e...

Страница 14: ...To Ethernet Converter setup is complete and all required connections made the unit should now be acces sible via the PC software Refer to the supplied Software Programming Guide for more information N...

Страница 15: ...Lockdown Fire Bell and cancel functions of the Redback A 4505C Connection is made from the A 2069 to the A 4505C via a minimum of 8 wires as shown in Fig 4 2 If standard Cat5 6 cable is used for the w...

Страница 16: ...wall plate are connected to the Lockdown Fire and Bell 24V outputs of the Redback A 4505C The cancel LED is not connected A mimimum of eight wires can be used if the ground connections of the Lockdown...

Страница 17: ...te Wall Plate Evac Alert Chime Cancel Mic Volume To Paging Console To Wall Plate Adapter CR2032 Backup Battery Holder Use 3V CR2032 Battery Only N C N O L R Audio Out Prebell Level V Over Level DIP Sw...

Страница 18: ...e for download on the microsoft website CHECK SD CARD HAS BEEN INSERTED CORRECTLY CHECK SD FORMATTED CORRECTLY CHECK MP3 FILES INSTALLED CHECK FORMAT OF MP3 It cannot be WAV or AAC MP3 files cannot be...

Страница 19: ...verified before switching any system component on Failure to follow the correct wiring configuration may result in damage to system components 6 0 FIRMWARE UPDATE It is possible to update the firmware...

Страница 20: ...act CONTROLS Lockdown Fire Rear Volume Voice over Rear Volume Bell Rear Volume Prebell Rear Volume Music Rear Volume Power On Off Switch Lockdown Switch Illuminated Push Switch Fire Switch Illuminated...

Отзывы: