9
3
MONITOR INFORMATION
Batt AH
The Battery amp hours can be set to offer a state of charge percentage, the range is from
1 – 9999Ah.
Note 1: This is a calculated guide based on the Battery Information on page 6.
Note 2: This setting is a guide only, the battery size does not need to be set for correct
function / charging.
Temp Comp. Coeff:
This screen shows and allows changes to the Temperature compensation coefficient and systems rated
voltage:
Temp Comp.
The temperature coefficient is the reduction in voltage
(millivolt) per degree Celsius rise in temperature.
(displayed in °C)
Temp Comp. Coeff
Rated Voltage
Auto
−30mV/°C/12V
Rated Voltage
The battery nominal voltage (12 V, 24 V or Auto)
Over Volt Disc.
This screen shows the Over Voltage Disconnect and Charge voltage limit setting:
Over Volt. Disc
The battery voltage level that will disconnect the solar
panel and stop charging the battery
Over Volt. Disc.
Charge Limit
16.0V
16.5V
Charge limit
The highest charging voltage allowed to be set.
Over Volt Rec.
This screen shows the Over Voltage Reconnect voltage setting and the Equalisation charge state:
Over Volt. Rec
The battery voltage level that will reconnect the solar
panel to the battery and resume charging after a previous
high voltage disconnection
Over Volt. Rec.
Equal. Charge
----V
15.8V
Charge limit
The Equalisation charging stage voltage setting.
Note: this will be zero for AGM battery setting and two 2 hours for Calcium and Standard battery types)
Absorb. Charge
This screen shows the Absorb & Float charging stage voltage levels:
Absorb.
Change
The battery voltage limit for the Absorb Stage of charging,
Absorb stage is when the battery is approaching full and
the regulator is maintaining a constant output voltage.
Absorb. Charge
Float Charge
13.6V
14.4V
Charge limit
The battery voltage limit for the Float stage of charging,
Float stage is when the battery is full and will be trickle
charged from the solar panel.