10
3
MONITOR INFORMATION
Absorb. Rec.
This screen shows the Absorption Recover voltage setting and the Low Voltage Reconnect setting:
Absorb. Rec
The voltage level that will re-trigger the charger
back into the Absorption stage of charge.
Absorb. Rec.
Low Volt. Rect.
11.5V
13.2V
Low Volt. Rect.
Not applicable.
Under Volt. Rect
This screen shows the Under Voltage Reconnect and Under Voltage Warning voltage levels:
Under Volt. Rect
The battery voltage level that will reconnect the
solar panel to the battery and resume charging
after a previous low voltage disconnection
Under Volt. Rect
Under Volt. Warn
11.5V
11.8V
Under Volt. Warn
The voltage level that will trigger the LED to turn
yellow, warning you that the battery voltage is
low. At this point you should manage your loads
and disconnect or turn off non-essential loads
to save battery power.
Low Volt. Disc
This screen shows the Low Voltage Disconnect and Discharge voltage limit for the battery:
Low Volt. Disc
Not applicable.
Low Volt. Disc
Discharge Limit
10.1V
10.5V
Discharge Limit
Not applicable.
Equalize Time
This screen shows the Equalize and Absorption charging stage time limits:
Low Volt. Disc
The time duration for the equalization charging
stage, this stage is required for battery
maintenance of permanent installations and will
trigger every 28 days
Equalize Time
Absorb Time
10min
---min
Discharge Limit
This is the Absorb charging stage time duration,
this setting is defaulted to 180 minutes, and can
be adjusted from 10 – 180 minutes.
Note: REDARC does not recommend changing this or any of the default settings.