background image

2

THE SOLAR REGULATOR REMOTE MONITOR

The REDARC Solar Regulator Remote Monitor allows users to monitor how their solar panels are performing 
and keep track of the charge state of the battery/s being used. 
The unit is simple to setup and control and provides an easy to read graphical interface, which can be 
modified to suit the users preferences.

WARNING & SAFETY INSTRUCTIONS

INST126-1

SAVE THESE INSTRUCTIONS — This manual 
contains IMPORTANT SAFETY INSTRUCTIONS for 
the REDARC Remote Monitor for REDARC Solar 
Regulators. 
DO NOT OPERATE THE SOLAR REGULATOR UNLESS 
YOU HAVE READ AND UNDERSTOOD THIS MANUAL 
AND THE SYSTEM IS SETUP AS PER THESE 
INSTRUCTIONS. REDARC RECOMMENDS THAT 
ANY REGULATOR/CHARGER BE INSTALLED BY A 
SUITABLY QUALIFIED PERSON.

WARNING

RISK OF EXPLOSIVE GASES:

Working in the vicinity of a lead-acid battery is 

dangerous. Batteries generate explosive gases 

during normal operation. For this reason, it is of 

utmost importance that you follow the instructions 

each time you use the Regulator. 

CAUTION

1. 

Solar Regulators should not be used by persons 
(including children) with reduced physical, 
sensory or mental capabilities, or lack of 
experience and knowledge, unless they are 
supervised or have been instructed on how to 
use the appliance by a person responsible for 
their safety.  Children should be supervised 
to ensure that they do not play with the Solar 
Regulator. 

2. 

Do NOT use the Solar Regulator to charge 
non-rechargeable batteries.  Doing so may 
result in harm to the user and/or damage to the 
regulator and/or solar blanket.  Only use the 
Solar Regulator for charging standard lead acid, 
calcium content, Gel & AGM type 12 V batteries.

3. 

Check the battery manufacturer’s data for your 
battery and ensure that the voltage of the  
charging profile you select does not exceed the 
manufacturer’s recommended maximum  
charging voltage. If the absorption and boost 
voltage for your battery type is too high, please 
select another charging profile. Do not change 
the original settings without confirming the 
battery manufacturer’s recommendations or 
consulting the battery manufacturer.

4. 

 The Solar Regulator is not intended to supply 
power to a low voltage electrical system  
other than to charge a battery.  

5. 

NEVER smoke or allow a spark or flame in 
vicinity of battery or engine. This may cause  
the battery to explode.

6. 

The remote monitor is not waterproof or 
designed for installation under bonnet or 
outdoors. Ensure the monitor is installed in a 
cool and dry environment.

7.  PERSONAL SAFETY PRECAUTIONS

To assist with the safe operation and use of the Solar 
Regulator:

a) 

Wear complete eye protection and clothing 
protection. Avoid touching eyes while working 
near a battery.

b) 

If Battery acid contacts your skin or clothing, 
remove the affected clothing and wash the 
affected area of your skin immediately with 
soap and water. If battery acid enters your eye, 
immediately flood the eye with running cold 
water for at least 10 minutes and seek medical 
assistance immediately.

Содержание SRPA-RM

Страница 1: ...Remote Monitor for Solar Regulator SRPA RM To suit SRPA0120 SRPA0240 SRPA0360 Solar Regulators...

Страница 2: ...use the Solar Regulator to charge non rechargeable batteries Doing so may result in harm to the user and or damage to the regulator and or solar blanket Only use the Solar Regulator for charging stan...

Страница 3: ...an 8 Pin RJ45 type Ethernet cable If a cable of different length is required REDARC recommend buying a cable of the required length rather than shortening the supplied cable 4 Do not forget your pass...

Страница 4: ...4 mm 4 5 114 mm 4 5 98 mm 3 9 98 mm 3 9 84 mm 3 3 84 mm 3 3 1 2 Mounting CAUTION The remote monitor is not waterproof or designed for installation under bonnet or outdoors Ensure the monitor is instal...

Страница 5: ...Info 1 3 Status Normal Fault No Mode Absorb Battery Info 2 3 Max Volts Min Volts 15 0 12 0 Battery Info 3 3 Current S O Charge Voltage 0 9A 92 14 6V S Panel Info 1 2 Amps Power Volts 0 9 16 8W 16 2 S...

Страница 6: ...ing performance of the system since it was connected Day Power supplied in the last 24 hours Charging Logs Month Total Day 0 0kWh 0 0kWh 0 0kWh Month Power supplied in the last 30 days Total Total pow...

Страница 7: ...s internal temperature displayed in C Regulator Info Temp Status 26 2 C OK Status The regulators status Pressing the ESC from any screen will take you to the MENU list 3 2 Menu These screens show deta...

Страница 8: ...is too high please select another charging profile Do not change the original settings without confirming the battery manufacturer s recommendations or consulting the battery manufacturer Batt Type Th...

Страница 9: ...top charging the battery Over Volt Disc Charge Limit 16 0V 16 5V Charge limit The highest charging voltage allowed to be set Over Volt Rec This screen shows the Over Voltage Reconnect voltage setting...

Страница 10: ...warning you that the battery voltage is low At this point you should manage your loads and disconnect or turn off non essential loads to save battery power Low Volt Disc This screen shows the Low Volt...

Страница 11: ...ight will increase the current draw Timing and durations of the backlight can be adjusted to suit individual needs Bklight The led backlight illumination time duration adjustable from 1 999 seconds De...

Страница 12: ...device must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class B digital device...

Страница 13: ...within the remote monitor s mounting bracket Plug A should be connected to the remote monitor and Plug B to the regulator The communication data cable is an 8 Pin RJ45 type Ethernet cable If a cable...

Страница 14: ...lia North America www redarcelectronics com warranty REDARC Corporation c o Shallco Inc 308 Component Dr Smithfield NC 27577 USA Australia 61 8 8322 4848 New Zealand 64 9 222 1024 UK Europe 44 0 20 39...

Страница 15: ...15 NOTES...

Страница 16: ...co nz www redarcelectronics co nz 64 9 222 1024 North America power redarcelectronics com www redarcelectronics com United States 1 704 247 5150 Canada 1 604 260 5512 Mexico 52 558 526 2898 UK Europe...

Отзывы: