28 | Troubleshooting
4.1 Error Codes
In the event of a fault with the unit installation, either battery or solar panel, ALL the LEDs on the unit
will flash to indicate the fault type.
Table 4.1.1:
Flashing Sequences
LED State
Description
1 flash (followed by 3.5 second off)
Internal Hardware Fault
2 flash (followed by 3.5 second off)
Unit under temp fault
3 flash (followed by 3.5 second off)
Unit over temp fault
4 flash (followed by 3.5 second off)
Output Battery Fault (Volts too high)
5 flash (followed by 3.5 second off)
Input under voltage (Battery)
*3
6 flash (followed by 3.5 second off)
Input over voltage (Battery or Solar panel) or
the Solar Panel is connected in reverse polairty.
*3 If the unit is being supplied power from the vehicle and solar simultaneously and ONE of those sources is
undervoltage, that specific source LED will flash 5 times. If the unit is being supplied power from the vehicle and
solar with BOTH sources under voltage, OR if the unit is being supplied power from one input only and that input
is undervoltage, ALL LED’s will flash 5 times.