37
10-MENU ITEMS AND OPERATION
Technical Dept. - All rights reserved - Reproduction is prohibited
h - Pellet Recipe
This function is for adapting the stove to the type of pellet in use. As there are many types of pellet available on the market, operation of
the stove can vary considerably according to the quality of the fuel. When the pellets clog up the brazier due to excess loading of fuel or
when the flames are high even at low power, or when the flames are low, it is possible to decrease/increase the amount of pellets in the
brazier:
Available values:
-3 = A decrease of 20% on the factory setting.
-2 = A decrease of 13% on the factory setting.
-1 = A decrease of 6% on the factory setting.
0% No changes.
3 = An increase of 10% on the factory setting.
2 = An increase of 6% on the factory setting.
1 = An increase of 3% on the factory setting.
Edit the recipe as follows:
• Press the “menu” key.
• Use the arrow keys to scroll through and select “Settings”
• Press “menu” to confirm.
• Scroll with the arrows and select “Pellet recipe’’
• Press “menu” to confirm.
• Alter the % with the + - keys.
• Press ‘’menu’’ to confirm and ‘’esc’’ to exit.
i - Variation % rpm smoke
In the event the installation presents problems in extracting smoke (lack of draft or even pressure in the duct), it is possible to increase
the smoke and ash extraction speed. This change resolves all the potential problems related to pellets clogging in the brazier and deposits
forming at the bottom of the brazier itself caused by poor quality fuel or fuel that produces a lot of ash. The extraction speed may be
altered between -30% to +50%, with increments of 10 percent at a time. Negative variation can be necessary if the flame is too low.
To alter this parameter, proceed as follows:
• Press the “menu” key.
• Use the arrow keys to scroll through and select “Settings”
• Press “menu” to confirm.
• Scroll with the arrows and select “Fumes rpm Var.”
• Press “menu” to confirm.
• Alter the % with the + - keys.
• Press ‘’menu’’ to confirm and ‘’esc’’ to exit.
j - Components test
This can be done only when the stove is off and allows you to select the components to be tested:
• Spark plug
: it is turned on for a fixed period of 1 minute during which the panel displays the countdown in seconds.
• Feed screw
: it is powered for a fixed period of 1 minute during which the panel displays the countdown in seconds.
• Extractor
: it is activated at 2500 rpm for a fixed period of 1 minute during which the panel displays the countdown in seconds.
• Exchanger
: enables you to conduct the test in V5 for a fixed period of 1 minute during which the panel displays the countdown in
seconds.
Enable the “Component test” function (only with stove off) as follows: