11-PROBLEMS/CAUSES/SOLUTIONS
Technical Dept. - All rights reserved - Reproduction is prohibited
ANOMALY
POSSIBLE CAUSES
SOLUTIONS
The boiler runs for a few minutes and
then switches off
Start-up phase is not completed
Repeat start-up
Temporary power cut
Wait for the automatic restart
Clogged smoke duct
Clean the smoke duct
Faulty or malfunctioning temperature
probes
Check and replace the probes
Faulty spark plug
Check the spark plug and replace it, if
necessary
Pellets accumulate in the brazier, the
glass of the door gets dirty and the
flame is weak
Insufficient combustion air
Clean the brazier and check that all
the holes are clear. Perform a general
cleaning of the combustion chamber and
smoke duct. Check that the air inlet is not
obstructed.
Damp or unsuitable pellets
Change the type of pellets
Faulty smoke evacuation motor
Check the motor and replace it, if necessary
The smoke evacuation motor does
not work
The boiler is not powered
Check the mains voltage and the
protection fuse
The motor is faulty
Check the motor and capacitor and replace
them, if necessary
Defective motherboard
Replace the electronic board
Control panel broken
Replace the control panel
In the automatic position the boiler
always runs at full power
Thermostat is set to minimum
Set the thermostat temperature again.
Room thermostat in position that always
detects cold.
Change the position of the probe
Faulty temperature probe.
Check the probe and replace it, if necessary.
Faulty or malfunctioning control panel.
Check the panel and replace it if necessary.