background image

ENGLISH 

15 

Code settings for zone allocation

 

The zone allocation for the sensor is set at the factory. The sensor can be allocated to a different zone as 
instructed below. 

 

Unscrew and remove the cover to the jumper compartment on the back of the sensor. 

 

In the area marked Zone Code there are eight pairs of metal contacts, each marked with a 
separate number. 

 

The number beside the pair of contacts that are strapped indicates the allocated zone. 

 

The sensor can be allocated to a different zone by pulling out the jumper and inserting the jumper 
for the required zone. 

 

MAINTENANCE 

Clean the product with a soft, damp cloth and then wipe dry.

 

Do not use abrasive or solvent-based 

detergents or aerosol products, as such substances can damage or discolour the product.

 Make sure no 

water gets into the product. Never try to clean the inside of the product. 

Batteries 

Make sure that batteries do not corrode or leak; this can cause permanent damage to the product.

 

Insert 

the batteries with the terminals (+/–) correctly positioned as marked inside the battery compartment.

 

Do 

not mix old and new batteries, or different types batteries.

 

Do not use rechargeable batteries. 

Recycle used batteries in accordance with local regulations.

 

Batteries must not be burned

Limitations of the alarm system

 

Not even the most advanced alarm systems can provide full protection from intruders or environmental 
impact.

 All alarm systems can be disabled for different reasons. 

Note that you may experience problems with the alarm system if:

 

 

the sensors are not placed within earshot of the places where people sleep, or are placed in 
remote parts of the building

 

 

the sensors are placed behind doors or other obstacles

 

 

intruders gain access via unprotected entrances, where there are no sensors 

 

intruders are able to bypass, block or disconnect the system or parts of it, by using technical 
equipment

 

 

the power supply to the sensors is inadaquate, or has been disconnected

 

 

the sensors are placed in unsuitable environmental/temperature conditions, e.g. to close to a 
source of heat. 

NOTE!

 

Incorrect maintenance is the most common cause of alarm faults. For this reason, you should test 

the alarm system at least once a week to make sure the sensors and sirens are working properly. 
An alarm system may entitle you to lower insurance premiums, but it can never replace insurance. 

Jula reserves the right to make changes. In the event of problems, please contact our service 
department. 
www.jula.com 

 

Jumper for 
zone code 

Default zone code: zone 1 

Содержание 441-082

Страница 1: ...rtsensor Instrukcja instalacji i obs ugi czujnika bramy gara owej Red Shield User Instructions for Red Shield Garage Door Sensor 441 082 SV Bruksanvisning i original NO Bruksanvisning i original PL In...

Страница 2: ...e 7 Kodeinnstilling for sonetildeling 8 Batterier 8 Alarmsystemets begrensninger 8 POLSKI 9 Zawarto zestawu 9 Uruchomienie czujnika bramy gara owej 9 Instalacja czujnika bramy gara owej 9 Monta za pom...

Страница 3: ...terier AAA ing r inte MONTERING Sensorn ska placeras p torr plats inomhus p garageportbladets nedre del och p portkarmen p s kert avst nd fr n extrema temperaturk llor radiatorer ugnar spisar och likn...

Страница 4: ...er beh ver ndras f r att l sa problem med att Smart Panel och sensorerna fungerar endast ibland eller inte alls eller st r andra system m ste ven huskoden p alla systemmoduler sensorer och sirener ndr...

Страница 5: ...ier ska avfallshanteras i enlighet med g llande regler Batterier f r inte br nnas Larmsystemets begr nsningar Inte ens de mest avancerade larmsystem kan ge fullst ndigt skydd mot inbrott eller milj h...

Страница 6: ...RING Sensoren skal plasseres p et t rt sted innend rs p garasjeportbladets nedre del og p portkarmen p sikker avstand fra ekstreme temperaturkilder radiatorer ovner komfyrer og liknende i henhold til...

Страница 7: ...lem med at Smartpanel og sensoren bare fungerer innimellom eller ikke i det hele tatt eller forstyrrer andre system m ogs boligsikkerhetskoden p alle systemmoduler sensorer eller sirener endres Boligs...

Страница 8: ...kastes i henhold til gjeldende regler Batterier m ikke brennes Alarmsystemets begrensninger Selv det mest avanserte alarmsystem kan ikke garantere 100 beskyttelse mot innbrudd eller milj betingede pr...

Страница 9: ...chodz w sk ad zestawu MONTA Czujnik nale y umie ci wy cznie w suchym miejscu wewn trz domu w dolnej cz ci bramy i na ramie bramy w odpowiedniej odleg o ci od ekstremalnych r de ciep a kaloryfery piece...

Страница 10: ...ikami lub panel i czujniki zak caj dzia anie innych system w kod domowy musi zosta zmieniony we wszystkich modu ach systemu czujniki i syreny Ustawienia kodu zmienia si zgodnie z poni szymi wskaz wkam...

Страница 11: ...go typu Nie u ywaj baterii wielokrotnego adowania Zu yte baterie nale y wyrzuci do odpowiedniego pojemnika zgodnie z obowi zuj cymi przepisami Zu ytych baterii nie wyrzucaj wraz z odpadami gospodarczy...

Страница 12: ...strze eniem prawa do zmian W razie ewentualnych problem w skontaktuj si telefonicznie z naszym dzia em obs ugi klienta pod numerem 801 600 500 Jula Poland Sp z o o ul Malborska 49 03 286 Warszawa Pols...

Страница 13: ...luded ATTACHMENT Positioning of the sensor in a dry place indoors on the lower part of the garage door and on the door frame at a safe distance from extreme temperature sources radiators ovens stoves...

Страница 14: ...ve been changed or need to be changed to resolve a problem whereby the Smart Panel and sensors only work occasionally or not at all or are disrupting other systems then the house code must also be cha...

Страница 15: ...eries Recycle used batteries in accordance with local regulations Batteries must not be burned Limitations of the alarm system Not even the most advanced alarm systems can provide full protection from...

Страница 16: ......

Отзывы: