TYPICAL INSTALLATIONS 

Well Casing

Foot Valve

Vent

Suction

Drain Plug

Well Seal

Priming Plug

To Service

Vent Plug

Pressure Gauge (optional) 

Clean-Out Plug

Relief Valve

Tank

Well Casing

Foot Valve

Vent

Suction

Well Seal

Priming Plug

Shut Off Valve

Union Couping (2 are required)

To Service

Vent
Plug

Drain

Pressure Gauge 

(optional)

Relief Valve

Drain Plug

Clean-Out Plug

Well Casing

Vent

Suction

Drain Plug

Well Seal

Priming Plug

To Service

Drain

Vent Plug

Pressure Gauge 

(optional)

Clean-Out Plug

Relief Valve

Inline Check Valve 

Tank

1-1/4" 

Galvanized Pipe

Well

Point

1-1/4" PVC Elbow

Well Casing

Foot Valve

Vent

Suction

Drain Plug

Well Seal

Priming Plug

To Service

Drain

Vent Plug

Pressure Gauge 

(optional)

Clean-Out Plug

Relief Valve

Tank

Figure 4 - Shallow Well, Inline Tank 

(with foot valve)

Figure 6 - Shallow Well, Tank-Mounted System 

(with foot valve)

Figure 5 - Shallow Well 

(with inline check valve)

Figure 3 - Shallow Well 

(with foot valve)

9

Содержание RJS-100-PREM

Страница 1: ...ket Sizes 6 Detailed Installation Instructions 7 Typical Installations 9 Pump to Tank Installation 10 Wiring Instructions 11 Priming the Pump 12 Maintenance 13 Troubleshooting 14 Replacement Parts 15...

Страница 2: ...onal Electrical Code NEC and with any local codes and ordinances Employ a licensed electrician s WARNING FOR DUAL VOLTAGE MOTORS 115 230 V Voltage change instructions are located in this manual s NOTI...

Страница 3: ...EEP THIS MANUAL ACCESSIBLE FOR FUTURE REFERENCE Description Voltage setting on pump verified and set to match voltage on the circuit breaker Foot valve for drilled wells or check valve for driven well...

Страница 4: ...VICE YOUR PRODUCT KNOW THE PRODUCT S APPLICATION LIMITATIONS AND POTENTIAL HAZARDS PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION FAILURE TO COMPLY WITH THESE INSTRUCTIONS COULD RESUL...

Страница 5: ...PVC pipe always use PVC primer to clean both pieces Apply the primer to the inside of one joint and the outside of the other joint so the primed areas meet Select Method 1 2 or 3 to affix the joints W...

Страница 6: ...the 1 1 4 male galvanized adapter into the suction opening Tighten securely but do not overtighten as this could crack the fitting 8 Attach the 1 1 4 PVC pipe from the well to the male adapter additio...

Страница 7: ...ump 3 Firmly clamp the unfinished end of the pipe with a pipe clamp 1 ft 30 cm from the top of the pipe This will prevent the pipe from dropping to the bottom of the well Lower this section into the w...

Страница 8: ...provides adequate room for services and protection from freezing temperatures The pump should be bolted to a good foundation preferably concrete and provided with adequate drainage Locating the pump a...

Страница 9: ...Well Casing Vent Suction Drain Plug Well Seal Priming Plug ToService Drain Vent Plug Pressure Gauge optional Clean Out Plug Relief Valve Inline Check Valve Tank 1 1 4 Galvanized Pipe Well Point 1 1 4...

Страница 10: ...afety relief valve s location is near the discharge of the pump and in an area with adequate drainage Be sure to direct the valve so that any water flow will not spray toward the pump or any other ele...

Страница 11: ...anging instructions The power lines should be connected to the pressure switch terminals marked Line Figure 7 It is recommended that a separate circuit be led from the distribution panel to the pump u...

Страница 12: ...5 m of suction line You will know when to stop because the pump will begin to pump water continuously 9 Once the pump begins pumping water continuously firmly tighten the priming plug with a wrench 1...

Страница 13: ...ure 8 s CAUTION ONLY DULY QUALIFIED PERSONS SHOULD PERFORM MAINTENANCE ON ELECTRICAL AND OR MECHANICAL DEVICES Disassembly 1 Shut off the power to the pump at the main service panel and disconnect the...

Страница 14: ...rictor valve to offset available capacity Add a larger tank 20 gallon or larger for additional capacity Problem Possible Cause Pump delivers water but not at rated capacity Leaks in suction or dischar...

Страница 15: ...4 5 6 7 8 305584007 Overhaul Kit RJS 75 PREM 3 4 5 6 7 8 305584008 Overhaul Kit RJS 100 PREM 3 4 5 6 7 8 305584009 Impeller Diffuser Kit RJS 50 PREM 3 5 6 305584010 Impeller Diffuser Kit RJS 75 PREM...

Страница 16: ...ructions Warranty will be VOID if any of the following conditions are found 1 Product is used for purposes other than those for which it was designed and manufactured 2 Product not installed in accord...

Отзывы: