red lion RJS-100-PREM Скачать руководство пользователя страница 4

INTRODUCTION

The shallow well jet pump is ideal for the supply of fresh water to rural 
homes, farms, and cabins. This pump is suitable for installations where the 
vertical distance from the pump to the water level does not exceed 25 ft 
(7.6 m), including drawdown (less at high altitudes). In offset installation, 
friction losses in the suction pipe must be taken into consideration  
(refer to 

Table 1, Friction Loss

). 

This instruction sheet provides you with the information required to  
safely own and operate your product. Retain these instructions for  
future reference.

The product you have purchased is of the highest quality workmanship and 
material, and has been engineered to give you long and reliable service. 
This product has been carefully tested, inspected, and packaged to ensure 
safe delivery and operation. Please examine your item(s) carefully to 
ensure that no damage occurred during shipment. If damage has occurred, 
please contact the place of purchase. They will assist you in replacement or 
repair, if required.

READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, 
OPERATE OR SERVICE YOUR PRODUCT. KNOW THE PRODUCT’S APPLICATION, 
LIMITATIONS, AND POTENTIAL HAZARDS. PROTECT YOURSELF AND OTHERS 
BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH  
THESE INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR 
PROPERTY DAMAGE!

VOLTAGE SETTING INSTRUCTIONS

To change the pump voltage from the factory setting of 230 volts, a 
qualified electrician should:

1.  Disconnect the power supply to the pump.

2.  Remove the cover from the motor terminal box.

In #2, the motor's switch is set for 115 V. The black voltage change device 
is pressed down onto both terminals with the white arrow on the voltage 
change device pointing directly to the 115 V arrow on the terminal board.

#2

 (Set to 115 V)

115

230

L2

L1

L2

L1

115

230

L2

L1

115

230

Orange

Brown

In #3, the motor's switch is set for 230 V. The black voltage change device is 
pressed down onto only one terminal with the white arrow on the voltage 
change device pointing directly to the 230 V arrow on the terminal board.

#3 

(Set to 230 V)

115

230

L2

L1

L2

L1

115

230

L2

L1

115

230

Orange

Brown

In #1, the motor's switch is shown before the black voltage change device is 
pressed down onto the voltage terminals.

NOTE:

 

DO NOT MOVE WHITE LEAD WIRES ON L1 & L2.

#1

115

230

L2

L1

L2

L1

115

230

L2

L1

115

230

Terminal 
Board

Voltage Change Device

Orange

Brown

Motor Terminal Box Cover

4

Содержание RJS-100-PREM

Страница 1: ...ket Sizes 6 Detailed Installation Instructions 7 Typical Installations 9 Pump to Tank Installation 10 Wiring Instructions 11 Priming the Pump 12 Maintenance 13 Troubleshooting 14 Replacement Parts 15...

Страница 2: ...onal Electrical Code NEC and with any local codes and ordinances Employ a licensed electrician s WARNING FOR DUAL VOLTAGE MOTORS 115 230 V Voltage change instructions are located in this manual s NOTI...

Страница 3: ...EEP THIS MANUAL ACCESSIBLE FOR FUTURE REFERENCE Description Voltage setting on pump verified and set to match voltage on the circuit breaker Foot valve for drilled wells or check valve for driven well...

Страница 4: ...VICE YOUR PRODUCT KNOW THE PRODUCT S APPLICATION LIMITATIONS AND POTENTIAL HAZARDS PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION FAILURE TO COMPLY WITH THESE INSTRUCTIONS COULD RESUL...

Страница 5: ...PVC pipe always use PVC primer to clean both pieces Apply the primer to the inside of one joint and the outside of the other joint so the primed areas meet Select Method 1 2 or 3 to affix the joints W...

Страница 6: ...the 1 1 4 male galvanized adapter into the suction opening Tighten securely but do not overtighten as this could crack the fitting 8 Attach the 1 1 4 PVC pipe from the well to the male adapter additio...

Страница 7: ...ump 3 Firmly clamp the unfinished end of the pipe with a pipe clamp 1 ft 30 cm from the top of the pipe This will prevent the pipe from dropping to the bottom of the well Lower this section into the w...

Страница 8: ...provides adequate room for services and protection from freezing temperatures The pump should be bolted to a good foundation preferably concrete and provided with adequate drainage Locating the pump a...

Страница 9: ...Well Casing Vent Suction Drain Plug Well Seal Priming Plug ToService Drain Vent Plug Pressure Gauge optional Clean Out Plug Relief Valve Inline Check Valve Tank 1 1 4 Galvanized Pipe Well Point 1 1 4...

Страница 10: ...afety relief valve s location is near the discharge of the pump and in an area with adequate drainage Be sure to direct the valve so that any water flow will not spray toward the pump or any other ele...

Страница 11: ...anging instructions The power lines should be connected to the pressure switch terminals marked Line Figure 7 It is recommended that a separate circuit be led from the distribution panel to the pump u...

Страница 12: ...5 m of suction line You will know when to stop because the pump will begin to pump water continuously 9 Once the pump begins pumping water continuously firmly tighten the priming plug with a wrench 1...

Страница 13: ...ure 8 s CAUTION ONLY DULY QUALIFIED PERSONS SHOULD PERFORM MAINTENANCE ON ELECTRICAL AND OR MECHANICAL DEVICES Disassembly 1 Shut off the power to the pump at the main service panel and disconnect the...

Страница 14: ...rictor valve to offset available capacity Add a larger tank 20 gallon or larger for additional capacity Problem Possible Cause Pump delivers water but not at rated capacity Leaks in suction or dischar...

Страница 15: ...4 5 6 7 8 305584007 Overhaul Kit RJS 75 PREM 3 4 5 6 7 8 305584008 Overhaul Kit RJS 100 PREM 3 4 5 6 7 8 305584009 Impeller Diffuser Kit RJS 50 PREM 3 5 6 305584010 Impeller Diffuser Kit RJS 75 PREM...

Страница 16: ...ructions Warranty will be VOID if any of the following conditions are found 1 Product is used for purposes other than those for which it was designed and manufactured 2 Product not installed in accord...