background image

4

20 Willow Springs Circle  |  York, PA 17406 USA

+1 (717) 767-6511  |  [email protected]  |  www.redlion.net

LIMITED WARRANTY

The Company warrants the products it manufactures against defects in materials and workmanship for a 

period limited to two years from the date of shipment, provided the products have been stored, handled, 

installed, and used under proper conditions. The Company’s liability under this limited warranty shall 

extend only to the repair or replacement of a defective product, at The Company’s option. The Company 

disclaims all liability for any affirmation, promise or representation with respect to the products.

The customer agrees to hold Red Lion Controls harmless from, defend, and indemnify RLC against 

damages, claims, and expenses arising out of subsequent sales of RLC products or products containing 

components manufactured by RLC and based upon personal injuries, deaths, property damage, lost profits, 

and other matters which Buyer, its employees, or sub-contractors are or may be to any extent liable, 

including without limitation penalties imposed by the Consumer Product Safety Act (P.L. 92-573) and 

liability imposed upon any person pursuant to the Magnuson-Moss Warranty Act (P.L. 93-637), as now in 

effect or as amended hereafter.
No warranties expressed or implied are created with respect to The Company’s products except those 

expressly contained herein. The Customer acknowledges the disclaimers and limitations contained herein 

and relies on no other warranties or affirmations.

Содержание PX2FCA

Страница 1: ... ensures that proper heater current is present when the control output is ON and little or no current is present when the output is OFF This provides indication of a shorted or open heater circuit A direct readout of process heater current can also be displayed if desired Heater current limit values and input scaling are programmed through the host PAX2 meter controller ORDERING INFORMATION MODEL ...

Страница 2: ...e option card slot Note that after the FlexCard top terminal case knock out is removed from the PAX2 case Reference Step 8 only another FlexCard with top terminals should be installed in the option slot location 4 Set the FlexCard Card Address DIP switch to match the option card slot position in which it will be installed Attach the appropriate slot location label to the rear of the top terminal b...

Страница 3: ...iv Input Resistance 5 Ω Accuracy 2 0 full scale 5 to 100 of range Frequency 50 to 400 Hz Overload 200 mA continuous Output on time delay for break alarm 1 second No Connection CT CT No Connection TO HEATER CONTROL LINE CURRENT TRANSFORMER NEUTRAL 120 240 V F1 F2 F3 F4 Rear Terminal Block Voltage Input F1 Current Input Input No Connection F2 F3 F4 0 20 mA Rear Terminal Block Voltage Input Current I...

Страница 4: ...d Red Lion Controls harmless from defend and indemnify RLC against damages claims and expenses arising out of subsequent sales of RLC products or products containing components manufactured by RLC and based upon personal injuries deaths property damage lost profits and other matters which Buyer its employees or sub contractors are or may be to any extent liable including without limitation penalti...

Отзывы: