NT24k Compact Series - Hardware Manual (Revised 06-02-2015)
65
NT24k-14FX6-POE
1.20.2
Specifications
POWER INPUT
Input Voltage: 22 - 49 VDC
Steady Input Current: 11.24 A @ 24 VDC (30W load on all PoE ports)
Inrush: 60.8 A / .20 ms @ 24 VDC
BTU/HR: 122
POWER OVER ETHERNET
PoE Standard IEEE 802.3af/at Gigabit PSE
PoE Output Power: 54 VDC / 30 Watts output (25.5 W at PD)
PSE Type: Type 2
CONNECTORS
10/100/1000BaseT: Eight RJ45 copper ports
100BaseFX: Six SC or ST duplex fiber ports
ENVIRONMENTAL
Operating Temperature: -40 °C to 80 °C
Storage Temperature: -40 °C to 80 °C
Operating Humidity: 10% to 95% (non condensing)
Operating Altitude: 0 to 10,000 ft.
Shock: 200 g @ 10 ms (bulkhead mounted)
Vibration: 50 g @ 5-200 Hz, Triaxial (bulkhead mounted)
MECHANICAL
Case Dimensions:
Height: 5.88” (14.92 cm)
Width: 4.28” (10.88 cm)
Depth: 5.54” (14.07 cm)
Weight: 3.35 lbs (1.52 kg)
Mount: 35 mm DIN-Rail
RECOMMENDED WIRING CLEARANCE
Front: 4” (10.16 cm)
Top: 4” (10.16 cm)
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]