2.25
Time
2.25.1
Basic
From the Basic Time Configuration View dialog, the administrator can define the system time, time zone, daylight
savings time and time source settings for the unit.
Click on the
Modify
button to make modifications to the unit’s time settings.
System Time:
This field displays the date/time of the system. The system date/time defaults to 2000-01-01
00:00:00 CST (UTC-06:00) at system start. The system date/time can be set manually but in the event of a
power cycle or reboot it will revert to the default value.
T
ime Source:
This field controls how the switch will automatically set its clock. The default value of "Set Time
Manually" means that the time the switch uses can only be set manually. Setting this field to either "SNTP" or
"PTP" causes the protocol to continuously update the system clock. Note that these must be enabled and
configured separately from the basic time configuration. PTP is a licensed option and is unavailable otherwise.