ORDERING INFORMATION

MODEL NO.

DESCRIPTION

PART NUMBER

ITMA

Intelligent Thermocouple Module

ITMA3035

APPLICATION

The temperature of certain industrial plastics is critical for melt flow of 

an injection molding process. Different plastic grades and the complexity 

of the mold determine required temperatures for efficient material flow. 

The master control room monitors the temperature of the melt flow of 

each injection mold machine. They will determine whether the operator 

may start the process on his machine or override the injection molding 

process. The injection molding machines are located throughout the plant, 

posing a thermocouple signal loss problem from long cable runs. The 

ITMA DC powered unit is mounted at the machine and uses the local 24 

VDC for power. The signal loss problem is solved using the 4 to 20 mA 

analog output for the long cable run to the master control room.

ERROR

POWER

VDC+

10

TC+

7

V+

4

I+

1

VDC-

TC-

12

11

9

8

6

5

V-

3

2

I-

+

-

MELT FLOW

MONITORED

MACHINE'S

POWER SUPPLY

24VDC

COMM

MASTER

CONTROL

ROOM

+

-

G Rail Installation

To install the ITMA on 

a “G” style DIN rail, 

angle the module so that 

the upper groove of the 

“foot” catches under the 

lip of the top rail. Push 

the module toward the 

rail until it snaps into 

place. To remove a 

module from the rail, 

push up on the bottom of 

the module while pulling 

out away from the rail.

T Rail Installation

To install the ITMA on a 

“T” style rail, angle the 

module so that the top groove 

of the “foot” is located over 

the lip of the top rail. Push 

the module toward the rail 

until it snaps into place. To 

remove a module from the 

rail, insert a screwdriver into 

the slot on the bottom of the 

“foot”, and pry upwards on 

the module until it releases 

from the rail.

INSTALLATION

The unit is equipped with a universal mounting foot for attachment to standard DIN style mounting rails, 

including G profile rail according to EN50035 - G32 , and top hat (T) profile rail according to EN50022 - 35 x 7.5 

and 35 x 15. The unit should be installed in a location that does not exceed the maximum operating temperature 

and provides good air circulation. Placing the unit near devices that generate excessive heat should be avoided.

Содержание ITMA

Страница 1: ...ment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired SPECIFICATIONS 1 POWER 9 to 32 VDC 1 75 W The power supply must have 300 mA for 200...

Страница 2: ...rols and heaters etc The cables should be run through metal conduit that is properly grounded This is especially useful in applications where cable runs are long and portable two way radios are used i...

Страница 3: ...e case and cut the wire jumper The jumper is located to the left side of the board as shown in the drawing POWER Connect DC power to terminals 10 and 12 observing proper polarity Be certain DC power i...

Страница 4: ...en turn on power and the previous settings will be loaded Field Calibration with a Thermocouple Calibrator 1 1 Enable the Ice Point Compensation on the Thermocouple Calibrator and set it to the Thermo...

Страница 5: ...Output increases to 0 8 mA 3 5 mA or 0 4 V nominal or more 4 19 Perform a Field Calibration See Section 1 0 1 2 3 4 5 6 7 9 8 10 ON 1 2 3 4 5 6 7 9 8 10 ON 1 2 3 4 5 6 7 9 8 10 ON 1 2 3 4 5 6 7 9 8 1...

Страница 6: ...S POWER SUPPLY 24VDC COMM MASTER CONTROL ROOM G Rail Installation To install the ITMA on a G style DIN rail angle the module so that the upper groove of the foot catches under the lip of the top rail...