background image

N-Tron

®

 Series 

308FX2, 309FX, 316TX, 317FX

Industrial Ethernet Switches

 

User Guide | December 2015

Содержание 308FX2

Страница 1: ...N Tron Series 308FX2 309FX 316TX 317FX Industrial Ethernet Switches User Guide December 2015 ...

Страница 2: ...rks of their respective owners CONTACT INFORMATION AMERICAS York PA 1 717 767 6511 Mobile AL 1 251 342 2164 Ballston Lake NY 1 518 877 5173 Hours 8am 6pm Eastern Standard Time UTC GMT 5 hours ASIA PACIFIC Shanghai P R China 86 21 6113 3688 x767 Hours 10am 6pm China Standard Time UTC GMT 8 hours EUROPE The Netherlands 31 33 4723 225 Hours 9am 6pm Central European Time UTC GMT 1 hour Website www red...

Страница 3: ...Warnings Précautions et avertissements de sécurité générale vi Electrical Safety Warnings Avertissements de sécurité électrique vii Environmental Safety Cautions and Warnings Sécurité environnementale mises en garde et avertissements viii UL cUL Hazardous Location Warning UL cUL Avertissement d emplacement dangereux viii Laser Safety Warning Consignes de sécurité relatives au laser ix Section 1 In...

Страница 4: ...Serial Cable 2 15 Hyper Terminal 2 15 Section 3 Operation and Maintenance 3 17 Introduction 3 17 300 TX FX Models Ports and Indicators 3 17 300 TX FX Models LED s and Operating Modes 3 18 Software Configuration 3 18 Command Line Interpreter CLI 3 18 Logging In password protection 3 19 CLI Navigation 3 20 CLI Menu Tree 3 20 CLI Menus and Commands 3 20 Home Menu 3 21 Home Menu Info Command 3 21 Syst...

Страница 5: ...e FCC Rules This product complies with Part 15 of the FCC A Rules Operation is subject to the following conditions 1 This device may not cause harmful Interference 2 This device must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC...

Страница 6: ...rdous materials as defined by the United States Environmental Protection Agency USEPA Red Lion recommends that all failed product be returned to Red Lion for failure analysis and proper disposal Toxic Emissions Red Lion equipment releases no toxic emissions Trademark Acknowledgments Ethernet is a registered trademark of Xerox Corporation ...

Страница 7: ...orts and one 100BaseFX multimode fiber port with ST or SC connectors 309FXE N XX YY Nine port eight 10 100BaseTX RJ 45 ports and one 100BaseFX singlemode 15km 40km or 80km fiber port with ST or SC connectors 316TX N 16 ports 16 10 100BaseTX RJ 45 ports 317FX N XX 17 port 16 10 100BaseTX RJ 45 ports and one 100BaseFX multimode port with ST or SC connectors 317FXE N XX YY 17 port 16 10 100BaseTX RJ ...

Страница 8: ... service redlion net Additional Product Information Additional product information can be obtained by contacting the local sales representative or Red Lion through the contact numbers and or e mail addresses listed on the inside of the front cover Warnings and Cautions Avertissements et mises en garde Warnings apply to situations where personal injury or death may result Mises en garde s appliquen...

Страница 9: ...pécifiée par Red Lion la protection fournie par l équipement peut être compromise WARNING Do not work on equipment or cables during periods of lightning activity AVERTISSEMENT Ne pas travailler sur le matériel ou les câbles pendant les périodes d activité de la foudre WARNING Properly ground the unit before connecting anything else to the unit Units not properly grounded may result in a safety ris...

Страница 10: ...G Do not operate the equipment in the presence of flammable gases or fumes Operating electrical equipment in such an environment constitutes a definite safety hazard AVERTISSEMENT Ne pas utiliser le matériel en présence de gaz ou de vapeurs inflammables L utilisation de matériel électrique dans un tel environnement constitue un danger certain WARNING Explosion Hazard Do not connect or disconnect a...

Страница 11: ...TENTION uniquement listés UL câblage avec cotes de température supérieure à 90 C Permis de classe I division 2 équipements fonctionnant à des températures allant jusqu à 70 C de température ambiante CAUTION Limited Operating Voltage range of 12 30V for Class I Division 2 installations ATTENTION limiter la plage de tension de fonctionnement de 12 30 V pour la classe I division 2 installations CAUTI...

Страница 12: ...Preface Revised 2015 12 04 x N Tron Series 300 TX FX Models User Guide ...

Страница 13: ...optic up link ports The two fiber links are capable of 2 Kilometers of 100 Mb communications without the use of repeaters The 308FXE2 is similar to the 308FX2 but is populated with singlemode extended range fiber optics 316TX The 316TX is an affordable 16 port copper port switch 309FX and 317FX The 309FX 317FX is a 9 17 port switch that has 8 16 copper ports plus an additional multimode fiber opti...

Страница 14: ...working Devices in Electric Power Stations American Bureau of Shipping ABS Type Approval Maritime and Offshore Applications Extended Environmental Specifications Support for Full Half Duplex Operation LED Link Activity Status Indication Autosensing Speed and Flow Control Up to 2 6 Gb s Maximum Throughput Industry Standard 35mm DIN Rail Mounted Enclosure Optional N View Monitoring on N units ...

Страница 15: ... 0 2 ms 24VDC Less than 100 mV Environmental Operating and Storage Temperature Operating Humidity Operating Altitude 40 C to 85 C 10 to 95 non condensing 0 to 10 000 ft Shock and Vibration Shock Vibration Seismic Note 200g 10ms 50g 5 200Hz Triaxial Unit must be bulkhead mounted to achieve these levels Reliability MTBF Mean Time Between Failure Two 2 Million Hours Network Media 10BaseT Cat 3 Cable ...

Страница 16: ...x current 0 5 A 8 5 Amp 0 7 ms 24VDC Less than 100 mV Environmental Operating Storage Temperature Operating Humidity Operating Altitude 40 C to 85 C 10 to 95 non condensing 0 to 10 000 ft Shock and Vibration Shock Vibration Seismic Note 200g 10ms 50g 5 200Hz Triaxial Unit must be bulkhead mounted to achieve these levels Reliability MTBF Mean Time Between Failure Two 2 Million Hours Network Media 1...

Страница 17: ...nt Input Ripple 10 30 VDC 400mA max 24VDC max current 1 0 A 7 0 Amp 0 8 ms 24VDC Less than 100 mV Environmental Operating Storage Temperature Operating Humidity Operating Altitude 40 C to 85 C 10 to 95 non condensing 0 to 10 000 ft Shock and Vibration Shock Vibration Seismic Note 200g 10ms 50g 5 200Hz Triaxial Unit must be bulkhead mounted to achieve these levels Reliability MTBF Mean Time Between...

Страница 18: ...30 VDC 440mA max 24VDC max current 1 0 A 8 5 Amp 0 8 ms 24VDC Less than 100 mV Environmental Operating Storage Temperature Operating Humidity Operating Altitude 40 C to 85 C 10 to 95 non condensing 0 to 10 000 ft Shock and Vibration Shock Vibration Seismic 200g 10ms 50g 5 200Hz Triaxial Reliability MTBF Mean Time Between Failure Two 2 Million Hours Network Media 10BaseT Cat 3 Cable 100BaseTX Cat 5...

Страница 19: ...rovals Safety Suitable for use in Class I Division 2 Groups A B C and D Hazardous Locations or Nonhazardous Locations only ATEX Zone 2 Category Ex nA IIC Gc DEMKO 03 ATEX 0316686U EMI EN61000 6 4 EN55011 Class A FCC 47 CFR Part 15 Subpart B Class A EMS EN61000 6 2 EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 Conducted Disturbances Conducted Low Frequency IEC60533 Sh...

Страница 20: ...1 8 N Tron Series 300 TX FX Models User Guide Introduction and Specifications Revised 2015 12 04 Certifications GOST R Certified ...

Страница 21: ...rtissement suivant avant de commencer l installation CAUTION FXE 40 and FXE 80 only CLASS 1 LASER PRODUCT Do not stare into the laser fiber optic connector when installing or operating the equipment ATTENTION FXE 40 et FXE 80 uniquement PRODUIT LASER CLASSE 1 PRODUIT LASER DE CLASSE 1 Ne pas regarder fixement le connecteur à fibre optique laser lors de l installation ou le fonctionnement du matéri...

Страница 22: ...ry All bonding equipment components shall be evaluated according to EN 60079 15 2010 and covered by a component certificate for the actual use When installing bonding components that will pass through an enclosure wall they must have a minimum of IP54 rating equal to the enclosure All electrical clearances must be maintained per the manufacturer s instructions of the bonding component or per EN 60...

Страница 23: ... into place Remove Vertical Mounted Unit 1 To remove the vertically mounted unit from 35mm DIN Rail carefully apply downward pressure on the unit 2 Rotate the unit upward and away from the 35mm DIN Rail and lift up for removal Horizontal Mounting 1 To mount the unit horizontally to the 35mm DIN Rail place the bottom edge of the bracket on the back of the unit against the DIN Rail s bot tom edge at...

Страница 24: ...tal clearance for fiber cable bend radius There should be at least 4 of clearance on both the top and bottom of the unit to allow proper ventilation Horizontal Mounting 1 To mount the unit to the 35mm DIN Rail place the top edge of the bracket on the back of the unit against the DIN Rail at a upward angle 2 Lower the bottom of the unit until it snaps into place Note When mounting the switch in the...

Страница 25: ...es into the Plug s observing polarity on unit 3 Plug the Voltage Input Plug s back into the side header 4 Tightening torque for the terminal block power plug is 0 22 Nm 0 162 Pound Foot 5 All LED s will flash ON momentarily 6 Verify the Power LED stays ON GREEN Note Only one plug must be connected to power for minimal operation Either V1 or V2 can be connected to power for minimal operation For re...

Страница 26: ...n the enclosure When using an unused PEM nut to connect a ground lug via a machine screw care should be taken to limit the penetration of the outer skin by less than 1 4 in Failure to do so may cause irreversible damage to the internal components of the switch Please note that the minimum cross sectional area of the grounding con ductor must be at least 14 18 gauge wire and it must be suitable for...

Страница 27: ...at5 straight through or crossover cable Note For units having the N View Option you can validate that all ports are working correctly by installing the N View OPC Server software The software is freely distributed on the Product CD and our website http www redlion net support software firmware Once the software is installed you should view the Ports Counter page to remotely monitor each connected ...

Страница 28: ... require a cable with a 9 pin or 25 pin sub D female connector for the PC end and a 9 pin male sub D connector for the 308FX2 309 316 317 end Table 7 shows the pin out and the connections for both types of cable Table 7 PC Port 25 Pin Female 9 Pin Female 308FX2 309 316 317 9 Pin Male Signal Name Pin Number Pin Number Pin Number Signal Name TXD 2 3 3 RXD RXD 3 2 2 TXD GND 7 5 5 GND Serial Cable Pin...

Страница 29: ...ed in Table 9 Table 9 Port LED Description LNK Link LED for Fiber Optic Port FX FXE models only TX 100MB s Fiber Optic Transmit Port FX FXE models only RX 100MB s Fiber Optic Receive Port FX FXE models only ACT Activity LED for Fiber Optic Port FX FXE models only RJ45 Ports Auto sensing 10 100BaseTX Connections Green LED lights when Power is connected 300 TX FX Models Front Panel NOTE Each RJ45 da...

Страница 30: ... between ports Unit LED s Software Configuration Command Line Interpreter CLI You can configure and or query all the important parameters of an N Tron series 308FX2 309 316 317 Industrial Ethernet switch using a Command Line Interpreter CLI These functions are accessible using the serial port marked COM To access the CLI 1 Connect a PC serial port to the 308FX2 309 316 317 V24 serial port and use ...

Страница 31: ...o read and modify the308FX2 309 316 317 switch parameters Note The admin password is admin 1 On a 308FX2 switch you must first press Escape to access the Management Console Function 2 Login enter username admin and press Enter 3 Password enter password admin and press Enter 4 The screen should display the CLI prompt See section on user defined password 5 You can now activate the commands of the CL...

Страница 32: ...Enable or disable each port negotiate Select autonegotiate or not for each port speed10 Force 10 Mb speed for each port speed100 Force 100 Mb speed for each port half Force half duplex for each port full Force full duplex for each port crossover Force crossover connection for each port filters Select traffic filter s filters are on 308FX2 only info Get info on Filters dis_nring Disable filters for...

Страница 33: ...me Menu Info command invokes a screen display of the Model Number Firmware version MAC Address and whether or not the N View function is enabled System Menu The System Menu commands Includes the following in Table 13 Table 13 Command Description Comment nview Get information about N View function Displays the model number firmware version MAC address and whether or not the N View function is enabl...

Страница 34: ...values of the switch settings MAC address enabled or disabled Disable or enable Enable or disable N View Choice is opposite of current state N View Menu Commands Note With the N option all ports have N View enabled in defaults but can be it can be disabled Rate for generation of MIB information frames is 6 4 seconds The FX Port is mapped to port 9 on the 309 and as port 17 on the 317 On the 308FX2...

Страница 35: ...es the switch to factory default settings and has these affects All ports are enabled All RJ45 ports are set for auto sensing All FX ports are set to 100 MHz and Full Duplex All RJ45 ports are set to auto MDIX as opposed to enabling crossover only N View is enabled on N units On the 308FX2 both ring filters are enabled The MAC address model number and firmware version are protected settings These ...

Страница 36: ...y to sense duplex mode and so uses the safest duplex mode half This is in accordance with the IEEE specification Thus you have one unit at 10 full and the other at 10 half basically functional but not ideal The unit at 10 full transmits without checking for busy and you get more data collisions Also the 10 full unit does not back off or retransmit based on the collision domain The same problem res...

Страница 37: ...N Tron Series 300 TX FX Models User Guide 3 25 Operation and Maintenance Revised 2015 12 04 Refer to the screens that follow for examples of executing each port command ...

Страница 38: ...ing ports The N Ring and 600 Series Ring filters are on the 308FX2 only and are either enabled or disabled The command choice presented is the opposite of the current state After entering bfilter you will be asked to Enter ports that are to receive General Broadcast frames Refer to the screens that follow for examples of executing each filters command Trouble Shooting The following procedure provi...

Страница 39: ...DUCTS INCLUDING ANY A WARRANTY OF MERCHANTABILITY B WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE OR C WARRANTY AGAINST INFRINGEMENT OF INTELLECTUAL PROPERTY RIGHTS OF A THIRD PARTY WHETHER EXPRESS OR IMPLIED BY LAW COURSE OF DEALING COURSE OF PERFORMANCE USAGE OF TRADE OR OTHERWISE Customer shall be responsible for determining that a Product is suitable for Customer s use and that such use complie...

Страница 40: ...3 28 N Tron Series 300 TX FX Models User Guide Operation and Maintenance Revised 2015 12 04 ...

Отзывы: