System
Info
Menu
System info provides information on each port, as shown in the example below. Note that this is real time status,
and some parameters (such as Rate, Duplex, and Crossover) will oscillate if not linked and not forced. To see
forced settings, go to switch/ports/info. See the sample “info” screen below.
Restore
(Restoring
Defaults)
The “restore” command restores the switch to factory default settings and has these affects:
•
All ports are enabled.
•
All RJ45 ports are set for auto-sensing. All FX ports are set to 100 MHz and Full Duplex.
•
All RJ45 ports are set to auto-MDIX (as opposed to enabling crossover only).
•
N-View
™
is enabled on –N units.
•
On the 308FX2, both ring filters are enabled.
The MAC address, model number, and firmware version are protected settings. These settings are
unaffected by
restoring factory defaults.
Switch
Menu
The available Switch Menu commands are described in
.
Table 15.
Command
Description
ports
Reconfigure individual port parameters
filters
Select traffic filters
Switch
Menu
Commands